background image

4 of 8

C2-XLGEP 

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Impact  

C2-XLGEP

Dairy / Delicatessen 
Precut & Packaged Produce

Electrical Data

4 ft

6 ft

8 ft

12 ft

Number of Fans—6W

1

2

2

3

Amperes

Watts

4 ft

6 ft

8 ft

12 ft

4 ft

6 ft

8 ft

12 ft

Evaporator Fan

120V

60Hz

Standard

0.50

1.00

1.00

1.50

39

78

78

117

120V

50Hz

Standard

0.55

1.10

1.10

1.65

42

84

84

126

230V

60Hz

Export

0.25

0.50

0.50

0.75

40

80

80

120

230V

50Hz

Export

0.28

0.56

0.56

0.84

44

88

88

132

120V

60Hz

Energy Efficient

0.26

0.52

0.52

0.78

18

36

36

54

230V

60Hz

Energy Efficient

NA

Canopy Anti-sweat Heaters

NA

0.75

0.75

1.00

45

90

90

120

Minimum Circuit Ampacity

120V

60Hz

Standard

0.70

1.95

1.95

2.70

120V

50Hz

Standard

0.75

2.05

2.05

2.85

230V

60Hz

Export

0.45

1.45

1.45

1.95

230V

50Hz

Export

0.48

1.51

1.51

2.04

120V

60Hz

Energy Efficient

0.46

1.47

1.47

1.98

230V

60Hz

Energy Efficient

NA

Maximum Over Current Protection 120V

20

20

20

20

Maximum Over Current Protection 230V

15

15

15

15

Standard Lighting

1 Row Canopy

0.26

0.51

0.51

0.77

30

59

59

85

Optional Lighting

Additional 1 Row Canopy

0.26

0.51

0.51

0.77

30

59

59

85

Additional 2 Row Canopy

0.51

1.02

1.02

1.54

59

118

118

170

1 Row Rail Light

0.26

0.51

0.51

0.77

30

59

59

85

1 Row Ledge Light

0.26

0.51

0.51

0.77

30

59

59

85

Optional Shelf Lighting

1 Row Shelf Receptacle

0.26

0.51

0.51

0.77

30

59

59

85

2 Row Shelf Receptacle

0.51

1.02

1.02

1.53

59

118

118

177

115V Lighting Circuit Total = Standard Li Total Optional Li Optional Shelf Lighting

230V Lighting Circuit Total = Multiply 115V Lighting Circuit Total by 0.52

Summary of Contents for Impact Excel C2X-LGEP

Page 1: ... ASSEMBLIES AND THERMOSTATS A 6W Fan Assembly 1 0058698 Fan Motor Evaporator 0142780 Fan Blade embossing toward motor B 0137880 Optional Adjustable 2 Refrigeration Thermostat Item Part Description Wiring Item HEATERS C Canopy Anti Sweat Heater 3 NA 4 ft 0109417 6 ft 0109417 8 ft 0109418 12 ft LAMPS AND BALLASTS D Ballast Electronic 4 0376409 2 lamps 0376410 3 lamps E Fluorescent Lamp 5 Replace wit...

Page 2: ...1 2 140 5 1 2 140 Distance between edges of external and center supports NA 31 1 8 790 40 5 8 1032 40 5 8 1032 Distance between edges of center supports 41 1 4 1048 NA NA 44 1118 Stub up area between front skid rail and splashguard 7 3 4 199 7 3 4 199 7 3 4 199 7 3 4 199 Electrical Service Electrical Field Wiring connection point B RH End of case to center of farthest knockout 38 1 4 972 64 3 8 16...

Page 3: ...SIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Merchandiser Liquid Line in 3 8 Merchandiser Suction Line in 7 8 Estimated Charge lb 4 ft 1 6 6 ft 2 3 8 ft 3 2 12 ft 4 5 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound 3 of 8 P N 0457232C HUSSMANN CORPORATION Bridgeton MO 63044 2483 U S A Note Optional Accessory Items 19 48...

Page 4: ...2 70 120V 50Hz Standard 0 75 2 05 2 05 2 85 230V 60Hz Export 0 45 1 45 1 45 1 95 230V 50Hz Export 0 48 1 51 1 51 2 04 120V 60Hz Energy Efficient 0 46 1 47 1 47 1 98 230V 60Hz Energy Efficient NA Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Optional Lighting Additional 1 Row Canopy 0 ...

Page 5: ...ERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND 1 2 3 Fans 4 ft 6 ft 8 ft 12 ft Case GROUND Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G R 5 4 W BL R 5 BL R G...

Page 6: ...Switch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 5 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 R R 5 Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS ...

Page 7: ...s placed in one of the top eight 8 locations it must comply with the angle depth requirements listed below Maximum Shelf Shelf Angle Depth 0 º 12 in 15 º 14 in or less 30 º 18 in or less 45 º 18 in or less NOTE Shelves placed in the lower positions may be up to 18 in deep when positioned at a 0 º angle Top Eight 8 Shelf Hole Locations 18 in 18 in 14 in 12 in 0 15 30 45 Angle Maximum Shelf Size 18 ...

Page 8: ...elf lamps is located behind the canopy on the left hand end when facing case of the merchandiser To access the ballast 1 Remove screws at bottom edge of canopy and rear of top panel 2 Remove the canopy by pulling it forward 3 Remove the top panel by lifting it up 4 Service or replace ballasts as required 5 Reassemble items as they were originally installed NOTE Rail lamp ballast is located behind ...

Reviews: