Remove Screws

Light Channel

Light Channel 

Hinge

Ballast

Light 

Channel

Foil-covered 
Anti-sweat 
Heater

Canopy

Canopy

Anti-Sweat Heater Wires 
with Purple Markers

Electrical Wireway

The ballast for the canopy and shelf lamps is
located behind the canopy on the left-hand end
(when facing case) of the merchandiser.  

To access the ballast:
1. Remove screws at bottom edge of canopy and

rear of light channel.

2. Lower light channel which will pivot on

hinge.

3. Service or replace ballasts as required.

4. Reassemble items as they were originally

installed.

NOTE

:  Rail lamp ballast is located in the

electrical raceway.

CANOPY ANTI-SWEAT HEATER

The canopy anti-sweat heater location is shown
below. Connections are in the electrical wireway.

Summary of Contents for impact Excel C2X-XLE

Page 1: ...an Blade FB 4780617 4W Energy Efficient Fan Assembly 1 0477653 Fan Motor Evaporator MO 4410544 0382383 Fan Blade FB 4780617 THERMOSTATS B 0411744 Standard Non adjustable 2 Defrost Thermostat CT 0411744 Item Part Description Wiring Item THERMOSTATS CONTINUED C Optional Adjustable Refrigeration Thermostat 3 HEATERS D Canopy Anti Sweat Heater 4 0488621 4 ft HE 4850616 0488622 6 ft HE 4850617 0488623 ...

Page 2: ...ween edges of external legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electrical Service Electrical Field Wiring connection point B RH End of case to center of stub up area 36 1 4 921 60 1 4 1530 84 1 4 2140 132 3 8 3363 Back of case to center of st...

Page 3: ...rature Pressure Chart to determine PSIG conversions Estimated Charge lb C2X XLE 4 ft 1 2 6 ft 1 6 8 ft 2 3 12 ft 3 3 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound Dimensions shown as inches and mm P N 0466004_G 3 of 10 HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A WWW HUSSMANN COM 55 3 4 1415 31 5 8 804 4 3 4 120 30 1 4 768 42 10...

Page 4: ...ort 0 48 0 56 0 76 1 04 120V 60Hz Energy Efficient 0 39 0 44 0 58 0 77 230V 60Hz Energy Efficient 0 30 0 32 0 40 0 50 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Anti sweat Heaters 120V 50 60Hz Standard 0 10 0 15 0 20 0 30 12 18 24 36 Standard Lighting T 8 Fluorescent 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Optional Lighting T 8 Fluorescen...

Page 5: ...I Total Display Area 3 Sq Ft Ft 3 50 ft2 ft 1 07 m2 m Shelf Area 4 Sq Ft Ft 6 38 ft2 ft 1 94 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refrigerated Volume less shelving and other unusable space Refrigerated Volume Unit of Length ft3 ft m3 m 3 Computed using ARI 1200 standard methodology Total Display Area ft2 m2 Unit of Length ft m 4 S...

Page 6: ...wo Row Canopy Connector BL BL W G R BL W R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy 6 5 6 6 Connector W B BL BL R BL R R R Optional Lighting 1 Row Rail B 4 ft 6 ft or 8 ft 12 ft 4 ft 6 ft or 8 ft 12 ft R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical groun...

Page 7: ...mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Three Rows of Shelves 4 ft case 6 6 6 B W 6 ft or 8 ft case 12 ft case BL BL R BL BL BL R W R B R 5 BL BL BL R R R R 6 6 6 B W BL BL R BL BL BL R W R B R 5 BL BL BL R R R R Purple BAND 4 120V Power Purple BAND 120V Neutral Anti Sweat Heater Canop...

Page 8: ...BL R BL R BL R BL 8 8 8 8 8 8 8 R BL 7 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 8 8 8 8 8 8 8 R BL 7 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND W Connector Optional Shelf Harness and LED Light Circuits for 3...

Page 9: ...lves The depth of the shelf used in the top eight 8 shelf hole locations is critical to case performance If a shelf is placed in one of the top eight 8 locations it must comply with the angle depth requirements listed below Maximum Shelf Shelf Angle Depth 0 º 12 in 15 º 14 in or less 30 º 18 in or less 45 º 18 in or less NOTE Shelves placed in the lower positions may be up to 18 in deep when posit...

Page 10: ...ballast for the canopy and shelf lamps is located behind the canopy on the left hand end when facing case of the merchandiser To access the ballast 1 Remove screws at bottom edge of canopy and rear of light channel 2 Lower light channel which will pivot on hinge 3 Service or replace ballasts as required 4 Reassemble items as they were originally installed NOTE Rail lamp ballast is located in the e...

Reviews: