REFRIGERATION DATA
Note:
This data is based on store temperature and
humidity that does not exceed 75
°
F and 55% R.H.
D5X-ULEP*
U
NLIT
L
IT
Discharge Air °F
32
30
Evaporator °F
28
26
Unit Sizing °F
26
24
Btu/hr/ft
D5X-ULEP* Parallel
Conventional
U
NLIT
‡‡
1510
1590
*Hussmann Peg Shelves are no longer
recommended.
‡‡ Add 10 Btu/hr/ft
per shelf row
for LED fixtures.
Add 20 Btu/hr/ft
per shelf row
for fluorescent lamps.
DEFROST DATA
Frequency Hrs
6
Defrost Water (lb/ft/day)
10.5
(± 15%
based on case configuration and
product loading).
O
FFTIME
D5X-ULEP
Time (minutes)
20
E
LECTRIC OR
G
AS
Not
Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO
**
D5X-ULEP
19
°
F / 9
°
F
Indoor Unit Only, Pressure Defrost
Termination**
48
°
F
**Use a Temperature Pressure Chart to
determine PSIG conversions.
PHYSICAL DATA
Estimated Charge (lb)***
D5X-ULEP
4 ft
1.9
6 ft
2.8
8 ft
3.7
12 ft
5.1
***This is an average for all refrigerant
types. Actual refrigerant charge may vary by
approximately half a pound.
3 of 8
P/N 0495782_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Impact
Excel
D5X-ULEP
Dairy & Delicatessen
Dimensions shown as in. and (mm).
Multi-deck, 6 Display Levels, Ultra Low Front
36
3
/
4
(934)
4
3
/
4
(120)
30
1
/
4
(767)
42
(1064)
42
(1064)
38
3
/
8
(975)
81
3
/
4
(2077)
D5X-ULEP
30
(762)
64
5
/
8
(1641)
FAN
C
O
I
L
10
1
/
4
(260)
3 In.
(77 mm)
Required
Air Gap
7
1
/
4
(183)
12
3
/
4
(324)
26
1
/
4
(667)
Refrigeration
Outlet
1
1
/
4
(32)
20
1
/
4
(514)
4 x 4 x 2
Electrical
Case to Case
Connections
61
3
/
4
(1568)
17
3
/
4
(451)
4
3
/
4
(121)
83
1
/
4
(2115)
ALL FIELD WIRING CONNECTION POINTS ARE ABOVE THE CASE.
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for
construction, materials & cleanability.