background image

Refrigeration 

Thermostat

2

To 
Condensing 
Unit

}

Light Blue

2, 4 & 6 Fans

120V N

EUTRAL

B

ROWN

  B

AND

120V P

OWER

Fans

1

B

ROWN

  B

AND

 

 
 

4 ft 
6 ft 
8 ft 

12 ft

 

 

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

=  F

IELD

 G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

=  C

ASE

 G

ROUND

4

4

3

3

3

4

4

4

4

4

4

Optional 

Two Row 

Canopy

Optional 

Three Row 

Canopy

Connector

4

BL

W

BL

W

G

R

BL

W

B

R

R

R

BL

BL

R

BL

R

R

R

BL

BL

R

BL

R

R

R

B

B

Orange or Tan Band

 

 

                                      3 Row Canopy

4

3

4

4

Connector

W

B

BL

BL

R

BL

R

R

R

B

D5X-ULEP

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

6 of 8

Fan Wiring
Offtime Defrost

Light Circuits

Summary of Contents for Impact Excel D5X-ULEP

Page 1: ...y A 7W Standard Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 Item Part Description Wiring Item THERMOSTATS B Optional Adjustable Refrigeration Thermostat 2 LAMPS AND BALLASTS C Ballast Electronic 3 0480130 2 lamps BA 4481676 0480131 3 lamps BA 4481654 04801...

Page 2: ...er of LH waste outlet 36 1 4 921 60 1 4 1530 84 1 4 2140 132 3 8 3363 RH End of case to the center of RH waste outlet 12 1 8 307 12 1 8 307 12 1 8 307 12 1 8 307 Back O S of case to center of waste outlets 36 3 4 933 36 3 4 933 36 3 4 933 36 3 4 933 Schedule 40 PVC drip pipe 1 1 4 32 1 1 4 32 1 1 4 32 1 1 4 32 Refrigeration Outlet Back of case to center of refrigeration outlet 26 1 4 665 26 1 4 66...

Page 3: ...IG conversions PHYSICAL DATA Estimated Charge lb D5X ULEP 4 ft 1 9 6 ft 2 8 8 ft 3 7 12 ft 5 1 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound 3 of 8 P N 0495782_B HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A WWW HUSSMANN COM Impact Excel D5X ULEP Dairy Delicatessen Dimensions shown as in and mm Multi deck 6 Display Levels Ultra L...

Page 4: ...0Hz Export 0 96 1 32 1 72 2 48 120V 60Hz Energy Efficient 0 80 0 96 1 40 2 00 230V 60Hz Energy Efficient 0 50 0 60 0 80 1 10 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Optional Lighting Additional 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Additional 2 Row Canopy 0 51 1 02 1 02 1...

Page 5: ...0 93 m3 m ARI Total Display Area 3 Sq Ft Ft 5 19 ft2 ft 1 58 m2 m Shelf Area 4 Sq Ft Ft 9 87 ft2 ft 3 01 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refrigerated Volume less shelving and other unusable space Refrigerated Volume Unit of Length ft3 ft m3 m 3 Computed using ARI 1200 standard methodology Total Display Area ft2 m2 Unit of Len...

Page 6: ... mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND 4 4 3 3 3 4 4 4 4 4 4 Optional Two Row Canopy Optional Three Row Canopy Connector 4 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band 3 Row Canopy 4 3 4 4 Connector W B BL BL R BL R R R B D5X ULEP Technical Data Sheet HUSSMANN CORPORATION Bridgeton MO 63044...

Page 7: ...e 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Six Rows of Shelves 4 ft case Connector 3 4 4 4 B W Connector 6 ft or 8 ft case 12 ft case BL BL R BL BL BL W R W R B R 3 B BL BL BL R R R R 4 R BL 4 R BL BL R BL R 4 R BL BL...

Page 8: ...le B Connector R BL R BL R BL R BL R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND W Connector Optional Shelf Harn...

Reviews: