background image

7 of 8

P/N 0463865_C

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

5

4

5

5

5

B

W

BL

BL

R

R

BL

R

BL

W

W

R

B

R

BL

BL

R

4

B

BL

BL

BL

BL

R

R

R

R

 

 

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

=  F

IELD

 G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

=  C

ASE

 G

ROUND

Optional Shelf Harness and Light Circuits for 
 
Four Rows of Shelves

4 ft case

Connector

5

4

5

5

5

B

W

Connector

6 ft or 8 ft case

12 ft case

BL

BL

R

R

BL

R

BL

W

W

R

B

R

BL

BL

R

4

B

BL

BL

BL

BL

R

R

R

R

5

4

5

5

5

B

W

BL

BL

R

R

BL

R

BL

W

W

R

B

R

BL

BL

R

4

B

BL

BL

BL

BL

R

R

R

R

Optional Shelf Lighting

Fluorescent Fixtures

Summary of Contents for Impact Excel M4X-E

Page 1: ...Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 Item Part De...

Page 2: ...ternal legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3...

Page 3: ...270 1350 Add 10 Btu hr ft per shelf row for LED fixtures Add 20 Btu hr ft per shelf row for fluorescent lamps DEFROST DATA Frequency Hrs 6 Defrost Water lb ft day 8 15 based on case configuration and...

Page 4: ...48 120V 60Hz Energy Efficient 0 80 0 96 1 40 2 00 230V 60Hz Energy Efficient 0 50 0 60 0 80 1 10 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Stan...

Page 5: ...l Display Area 3 Sq Ft Ft 3 80 ft2 ft 1 16 m2 m Shelf Area 4 Sq Ft Ft 6 71 ft2 ft 2 05 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refriger...

Page 6: ...BL R BL R R R Optional Lighting 1 Row Rail B 4 ft 6 ft or 8 ft 12 ft 4 ft 6 ft or 8 ft 12 ft R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components...

Page 7: ...G All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Four Rows of Shelve...

Page 8: ...R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING...

Reviews: