background image

8 of 8

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

M4X-EP 

Technical Data Sheet

R

BL

R

BL

R

BL

R

BL

R

BL

R

BL

R

BL

6

6

6

6

6

6

6

R

BL

5

B

B

W

W

BL

R

G

4 ft case

6 ft or 8 ft case

12 ft case

(TYP)

Shelf Light

Plug & Receptacle

B

Connector

R

BL

R

BL

R

BL

R

BL

R

BL

R

BL

R

BL

6

6

6

6

6

6

6

R

BL

5

B

B

W

W

BL

R

R

BL

R

BL

R

BL

R

BL

R

BL

R

BL

R

BL

6

6

6

6

6

6

6

R

BL

5

B

B

W

W

BL

R

 

 

R = Red          G = Green          BL = Blue          B = Black          W = White

=  120V P

OWER

=  120V N

EUTRAL

=  F

IELD

 G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

=  C

ASE

 G

ROUND

W

Connector

Optional Shelf Harness and LED Light Circuits for 
 
 
3, 4, 5, 6 & 7 Rows of Shelves

Optional Shelf Lighting
LED Fixtures

Summary of Contents for Impact Excel M4X-EP

Page 1: ...nal Adjustable Refrigeration Thermostat 2 LAMPS BALLASTS LED FIXTURES AND POWER SUPPLY C Ballast Electronic 3 0480130 2 lamps BA 4481676 0480131 3 lamps BA 4481654 0480132 4 lamps BA 4481677 D Fluores...

Page 2: ...xternal legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3...

Page 3: ...t Unlit Shelves M4X EP Parallel Conventional UNLIT 1095 1190 Add 10 Btu hr ft per shelf row for LED fixtures Add 20 Btu hr ft per shelf row for fluorescent lamps DEFROST DATA Frequency Hrs 6 Defrost W...

Page 4: ...Export 0 76 0 92 1 32 1 88 120V 60Hz Energy Efficient 0 58 0 68 0 96 1 34 230V 60Hz Energy Efficient 0 40 0 44 0 60 0 80 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protecti...

Page 5: ...otal Display Area 3 Sq Ft Ft 3 80 ft2 ft 1 16 m2 m Shelf Area 4 Sq Ft Ft 6 71 ft2 ft 2 05 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refri...

Page 6: ...3 4 4 Connector W B BL BL R BL R R R Optional Lighting 1 Row Rail B 4 ft 6 ft or 8 ft 12 ft 4 ft 6 ft or 8 ft 12 ft R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND...

Page 7: ...G All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Four Rows of Shelve...

Page 8: ...R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNIN...