P/N 0463886_C

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

Impact  

Excel

M4X-GEP

Meat and Delicatessen

ESTIMATED SHIPPING WEIGHT 

5

Case

Solid End

4 ft

6 ft

8 ft

12 ft

(each)

lb 

(kg)

700 (318)

900 (408)

1000 (454)

1400 (635)

100 (45)

5

Actual weights will vary according to optional kits included.

Product Data

ARI Refrigerated Volume 

(Cu Ft/Ft)

7.63 ft

3

/ft  (0.71 m

3

/m)

Recommended Usable Cube 

2  

(Cu Ft/Ft)

6.06 ft

/ft  (0.56 m

/m)

ARI Total Display Area 

3  

(

Sq Ft/Ft)

3.80 ft

2

/ft  (1.16 m

/m)

Shelf Area 

4

(Sq Ft/Ft)

6.69 ft

2

/ft  (2.04 m

/m)

1

Computed using ARI 1200 standard methodology: Refrigerated Volume, ft

3

[m

3

]/Unit of Length, ft [m]

2

ARI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft

3

/ft [m

3

/m]

3

Computed using ARI 1200 standard methodology:  Total Display Area, ft

2

[m

2

]/Unit of Length, ft [m]

4

Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann 

Product Reference Guide

. The standard shelf complement for this model is (2) rows of 16-inch shelves and (1) row of 

18-inch shelf.

eparately from fans.

Summary of Contents for Impact Excel M4X-GEP

Page 1: ...Ft Only A 4W Standard Fan Assembly 1 0392457 Fan Motor Evaporator MO 4410101 0382383 Fan Blade FB 4780617 4W Energy Efficient Fan Assembly 1 0477653 Fan Motor Evaporator MO 4410544 0382383 Fan Blade...

Page 2: ...054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electrical Service Electrical Field Wiring co...

Page 3: ...IT 1000 1090 Add 10 Btu hr ft per shelf row for LED fixtures Add 20 Btu hr ft per shelf row for fluorescent lamps DEFROST DATA Frequency Hrs 6 Defrost Water lb ft day 8 15 based on case configuration...

Page 4: ...20V 60Hz Energy Efficient 0 58 0 68 0 96 1 34 230V 60Hz Energy Efficient 0 40 0 44 0 60 0 80 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard...

Page 5: ...otal Display Area 3 Sq Ft Ft 3 80 ft2 ft 1 16 m2 m Shelf Area 4 Sq Ft Ft 6 69 ft2 ft 2 04 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refri...

Page 6: ...6 ft or 8 ft 12 ft R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED...

Page 7: ...G All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Four Rows of Shelve...

Page 8: ...R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNIN...

Reviews: