background image

7 of 8

P/N 0463886_C

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

4

3

4

4

4

B

W

BL

BL

R

R

BL

R

BL

W

W

R

B

R

BL

BL

R

3

B

BL

BL

BL

BL

R

R

R

R

 

 

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

=  F

IELD

 G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

=  C

ASE

 G

ROUND

Optional Shelf Harness and Light Circuits for 
 
Four Rows of Shelves

4 ft case

Connector

4

3

4

4

4

B

W

Connector

6 ft or 8 ft case

12 ft case

BL

BL

R

R

BL

R

BL

W

W

R

B

R

BL

BL

R

3

B

BL

BL

BL

BL

R

R

R

R

4

3

4

4

4

B

W

BL

BL

R

R

BL

R

BL

W

W

R

B

R

BL

BL

R

3

B

BL

BL

BL

BL

R

R

R

R

Optional Shelf Lighting

Fluorescent Fixtures

Summary of Contents for Impact Excel M4X-GEP

Page 1: ...Ft Only A 4W Standard Fan Assembly 1 0392457 Fan Motor Evaporator MO 4410101 0382383 Fan Blade FB 4780617 4W Energy Efficient Fan Assembly 1 0477653 Fan Motor Evaporator MO 4410544 0382383 Fan Blade...

Page 2: ...054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electrical Service Electrical Field Wiring co...

Page 3: ...IT 1000 1090 Add 10 Btu hr ft per shelf row for LED fixtures Add 20 Btu hr ft per shelf row for fluorescent lamps DEFROST DATA Frequency Hrs 6 Defrost Water lb ft day 8 15 based on case configuration...

Page 4: ...20V 60Hz Energy Efficient 0 58 0 68 0 96 1 34 230V 60Hz Energy Efficient 0 40 0 44 0 60 0 80 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard...

Page 5: ...otal Display Area 3 Sq Ft Ft 3 80 ft2 ft 1 16 m2 m Shelf Area 4 Sq Ft Ft 6 69 ft2 ft 2 04 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refri...

Page 6: ...6 ft or 8 ft 12 ft R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED...

Page 7: ...G All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Four Rows of Shelve...

Page 8: ...R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNIN...

Reviews: