background image

2 of 6

M5EPlus 

Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Engineering

Plan Views

Waste Outlet

Water Seal

(see note)

Refrigeration

Outlet

Electrical

A

B

C

D

72 

1

/

4

 

(1835)

40 

5

/

8

(1032)

27 

5

/

8

(703)

30 

5

/

8

(778)

1

/

8

 

(105)

29 

3

/

8

(747)

46 

1

/

4

(1174)

1

/

2

 

(114)

1

/

2

 

(140)

3

/

8

 

(35)

40 

5

/

8

(1032)

35 

3

/

8

(897)

4

(102)

FRONT

1

/

2

 

(114)

30 

1

/

2

(775)

Dimensions shown as in. and (mm).

Meat & Produce

8 ft

12 ft

General

(A)

Case Length 

(without ends or partitions)

96 

3

/

8

(2448)

144 

1

/

2

(3670)

Maximum O/S dimension of case back to front 

(includes bumper)

46 

1

/

4

(1174)

46 

1

/

4

(1174)

Back of case to front of splashguard

38 

5

/

(981)

38 

5

/

(981)

Back of case to O/S edge of front skid rail

29 

1

/

(749)

29 

1

/

(749)

Width of skid rail

1

/

(114)

1

/

(114)

RH end of case to outside edge of external support

1

/

2

(140)

1

/

2

(140)

Distance between edges of external support and center support

40 

5

/

(1032)

40 

5

/

(1032)

Distance between edges of center supports

NA

44  (1118)

Stub-up area between front skid rail and splashguard

7 (178)

7 (178)

Electrical Service                         

(Electrical Field Wiring connection point)

(B)

RH End of case to center of farthest knockout

88 

3

/

(2245)

136 

1

/

(3467) 

Back of case to center of knockout

35 

3

/

(899)

35 

3

/

(899)

Length of electrical raceway

34 

5

/

(878)

34 

5

/

(878)

Waste Outlet

(C)

RH End of case to the center of waste outlet

24 

1

/

(613)

72 

1

/

(1835)

LH End of case to the center of waste outlet

72 

1

/

(1835)

72 

1

/

(1835)

Back O/S of case to center of waste outlet

27 

1

/

(699)

27 

1

/

(699)

Water Seal

Edge of water seal to center of waste outlet

4 (102)

4 (102)

Outside diameter of the drip pipe

1

/

(38)

1

/

(38)

NOTE: Water seal outlet must clear front skid rail;
water seal rotation in forward direction only due to low base.

Refrigeration Outlet

Back of case to center of refrigeration outlet

30 

5

/

(778)

30 

5

/

(778)

(D)

RH end of case to center of refrigeration outlet

9 (230)

9 (230)

05-2003

Summary of Contents for Impact Excel M5EP

Page 1: ...4 Item Part Description Wiring Item FAN ASSEMBLIES AND THERMOSTATS A 9W Fan Assembly 1 0047000 Fan Motor Evaporator 0380485 Fan Blade embossing toward motor C 0137880 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0428648 Ballast Electronic 2 lamps 4 D 0428649 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace with like fixtures ...

Page 2: ... support and center support 40 5 8 1032 40 5 8 1032 Distance between edges of center supports NA 44 1118 Stub up area between front skid rail and splashguard 7 178 7 178 Electrical Service Electrical Field Wiring connection point B RH End of case to center of farthest knockout 88 3 8 2245 136 1 2 3467 Back of case to center of knockout 35 3 8 899 35 3 8 899 Length of electrical raceway 34 5 8 878 ...

Page 3: ...sure Chart to determine PSIG conversions PHYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb M5EPLUS 8 ft 3 7 12 ft 5 1 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound Length Added to Lineup by Each End in 1 1 2 Each Insulated Partition in 1 1 2 3 of 6 P N 0457237A HUSSMANN CORPORATION Bridgeton M...

Page 4: ...Fans 120V 60Hz 3 00 4 40 With Energy Efficient Fans 120V 60Hz 1 72 2 48 With Export Fans 230V 50Hz 1 72 2 48 Maximum Over Current Protection 120V 20 20 Export 230V 50Hz 15 15 Electric Defrost Heaters 208V 1Φ Φ NA NA NA NA Gas Defrost Heaters 208V NA NA NA NA Standard Lighting 8 ft 12 ft 8 ft 12 ft 1 Row Canopy 0 51 0 77 59 85 Optional Lighting 1 Row Canopy and 1 Row Rail 1 02 1 54 118 170 2 Row Ca...

Page 5: ...ve mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 4 6 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light...

Page 6: ...ot models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Optional Lighting 3 Row Canopy 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W 4 BL R R BL BL 3 BL R R BL BL 3 4 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 3 4 4 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V ...

Reviews: