background image

7 of 8

P/N 0463888_C

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

4

3

4

4

4

4

B

W

BL

BL

R

BL

R

BL

R

BL

W

R

W

R

B

R

BL

BL

R

3

B

BL

BL

BL

BL

BL

R

R

R

R

R

 

 

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

=  F

IELD

 G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

=  C

ASE

 G

ROUND

Optional Shelf Harness and Light Circuits for 
 
Five Rows of Shelves

4 ft case

Connector

4

3

4

4

4

4

B

W

Connector

6 ft or 8 ft case

10 ft or 12 ft case

BL

BL

R

BL

R

BL

R

BL

W

R

W

R

B

R

BL

BL

R

3

B

BL

BL

BL

BL

BL

R

R

R

R

R

4

3

4

4

4

4

B

W

BL

BL

R

BL

R

BL

R

BL

W

R

W

R

B

R

BL

BL

R

3

B

BL

BL

BL

BL

BL

R

R

R

R

R

Optional Shelf Lighting

Fluorescent Fixtures

Summary of Contents for Impact Excel M5X-GEP

Page 1: ...Ft and 10 Ft Only A 7W Standard Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 F...

Page 2: ...1 1 2 1054 29 1 2 749 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electr...

Page 3: ...to determine PSIG conversions Estimated Charge lb M5X GEP 4 ft 1 9 6 ft 2 5 8 ft 3 7 10 ft 4 4 12 ft 5 1 This is an average for all refrigerant types Actual refrigerant charge may vary by approximate...

Page 4: ...2 48 120V 60Hz Energy Efficient 0 80 0 96 1 40 1 56 2 00 230V 60Hz Energy Efficient 0 50 0 60 0 80 0 90 1 10 Maximum Over Current Protection 120V 20 20 20 20 20 Maximum Over Current Protection 230V 1...

Page 5: ...m ARI Total Display Area 3 Sq Ft Ft 4 40 ft2 ft 1 34 m2 m Shelf Area 4 Sq Ft Ft 8 36 ft2 ft 2 55 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 AR...

Page 6: ...Three Row Canopy Connector 4 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy 3 Row Canopy B 4 ft 6 ft...

Page 7: ...nents must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Five Rows of Shelves 4 ft case...

Page 8: ...R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNIN...

Reviews: