background image

2 of 9

P2X-EP 

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

Engineering

Plan Views

Dimensions shown as inches and (mm).

Produce

10-2004

NOTE: Case-to-Case Electrical Connections 
are made IN FRONT OF SPLASHGUARD. 

3

/

(120)

Splashguard

31 

5

/

(804)

42

 

(1064)

A

41 

1

/

(1054)

3 In. 

(77 mm)

 

Required 

Air Gap

Refrigeration 

Outlet

Electrical 

Stub Up Area 

6 x 6 

(152x152)

 

Waste Outlet

Waste Outlet

FRONT

26 

1

/

(665)

B

D

8

 

(203)

1

/

(115)

12 

1

/

(307)

41 

1

/

(1054)

43 

7

/

(1114)

C

Wireway

3

/

(120)

26 

1

/

(673)

1

/

(108)

24

 

(612)

33 

1

/

(851)

Electrical 
Field 
Connection

30 

1

/

(768)

P2X

4 ft

6 ft

8 ft

12 ft

General

(A)

Case Length 

(without ends or partitions)

48 

3

/

8

(1229)

72 

3

/

8

(1838)

96 

3

/

8

(2448)

144 

1

/

2

(3670)

(Each end and insulated partition adds 1 

1

/

in. (38 mm) to case line up.)

Maximum O/S dimension of case back to front 

(includes bumper)

42 (1064)

42 (1064)

42 (1064)

42  (1064)

Back of case to front of splashguard

33 

1

/

(851)

33 

1

/

(851)

33 

1

/

(851)

33 

1

/

(851)

Back of case to O/S edge of front leg

30 

1

/

(768)

30 

1

/

(768)

30 

1

/

(768)

30 

1

/

(768)

Distance between edges of external legs and center legs

NA

29 

1

/

(750)

41 

1

/

(1054)

41 

1

/

(1054)

Distance between edges of center legs

NA

NA

NA

43 

7

/

(1114)

Distance between front legs and splashguard

3

/

4

(70)

3

/

4

(70)

3

/

4

(70)

3

/

4

(70)

Electrical Service             

(Electrical Field Wiring connection point)

(B)

RH End of case to center of stub up area

36 

1

/

(921)

60 

1

/

(1530)

84 

1

/

(2140)

132 

3

/

(3363)

Back of case to center of stub up area

24 (612)

24 (612)

24 (612)

24 (612)

Length of electrical wireway

26 

1

/

(673)

26 

1

/

(673)

26 

1

/

(673)

26 

1

/

(673)

(C)

RH End of case to LH end of wireway

42 

1

/

(1070)

66 

1

/

(1680)

90 

1

/

(2289)

138 

1

/

(3511)

Waste Outlets  

(One each end)

(D)

RH End of case to the center of LH waste outlet

36 

1

/

(921)

60 

1

/

(1530)

84 

1

/

(2140)

132 

3

/

(3363)

RH End of case to the center of RH waste outlet

12 

1

/

(307)

12 

1

/

(307)

12 

1

/

(307)

12 

1

/

(307)

Back O/S of case to center of waste outlets

31 

5

/

(804)

31 

5

/

(804)

31 

5

/

(804)

31 

5

/

(804)

Schedule 40 PVC drip pipe

1

/

(32)

1

/

(32)

1

/

(32)

1

/

(32)

Refrigeration Outlet

Back of case to center of refrigeration outlet

26 

1

/

(665)

26 

1

/

(665)

26 

1

/

(665)

26 

1

/

(665)

RH end of case to center of refrigeration outlet

8  (203)

8  (203)

8  (203)

8  (203)

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

4

Merchandiser Liquid Line (in.)

3

/

8

Merchandiser Suction Line (in.)

7

/

8

Wireway

Summary of Contents for Impact Excel P2X-EP

Page 1: ...de FB 0142780 6 Ft Only A 4W Standard Fan Assembly 1 0392457 Fan Motor Evaporator MO 4410101 0382383 Fan Blade FB 4780617 4W Energy Efficient Fan Assembly 1 0477653 Fan Motor Evaporator MO 4410544 038...

Page 2: ...al legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70...

Page 3: ...Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lbs P2X EP 4 ft 6 ft 8 ft 2 7 12 ft 3 9 This is an average for all refrigerant types actual refrigerant charge may vary...

Page 4: ...0Hz Energy Efficient 0 30 0 32 0 40 0 50 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting T 8 fluorescent 1 Row Canopy 0 26 0 51 0 51...

Page 5: ...m3 m ARI Total Display Area 3 Sq Ft Ft 3 39 ft2 ft 1 03 m2 m Shelf Area 4 Sq Ft Ft 3 87 ft2 ft 1 18 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2...

Page 6: ...Canopy Optional Three Row Canopy Connector 4 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band 3 Row Canopy 4 3 4 4 Connector W B BL BL R BL R R R B 4 ft 6 ft or 8 f...

Page 7: ...FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for...

Page 8: ...6 6 R BL R BL R BL 6 6 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground an...

Page 9: ...L R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNI...

Reviews: