background image

REFRIGERATION DATA

Note:

This data is based on store temperature and

humidity that does not exceed 75°F and 55% R.H.

P2X-EP

U

NLIT

L

IT

Discharge Air °F

39

39

Evaporator °F

34

34

Unit Sizing °F

32

32

Btu/hr/ft — Unlit Shelves

P2X-EP

‡‡

Parallel

Conventional

U

NLIT

910

910

‡‡ Add 10 Btu/hr/ft 

per shelf row

for LED fixtures.

Add 20 Btu/hr/ft 

per shelf row

for fluorescent lamps.

DEFROST DATA

P2X-EP

Frequency (hr)

N

ONE

Defrost Water (lb/ft/day)

6

(±15% based on case configuration and

product loading.

O

FFTIME

P2X-EP

Time (minutes)

N

ONE

E

LECTRIC OR

G

AS

Not Recommended

CONVENTIONAL CONTROLS

Low Pressure Backup Control

P2X-EP

CI/CO*

27°F / 17°F

Indoor Unit Only, Pressure Defrost

Termination*

48°F

*Use a Temperature Pressure Chart to

determine PSIG conversions.

Estimated Charge (lbs)**

P2X-EP

4 ft

6 ft

8 ft

2.7

12 ft

3.9

**This is an average for all refrigerant types

actual refrigerant charge may vary by

approximately half a pound.

3 of 9

P/N 0463873_B

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

31 

5

/

(804)

3

/

4

 

(120)

30 

1

/

4   

(768)

42 

 

(1064)

33 

1

/

(851)

26 

1

/

(665)

Refrigeration 

Outlet

30 

1

/

4

 

(768)

42 

1

/

2

 

 

(1080)

34 

5

/

8

 

(878)

36 

1

/

4

 

(920)

FAN


L

P2X-EP

28 

5

/

8

 

(727)

3 In. 

(77 mm) 

Required 

Air Gap

1

/

(183)

31

 

(787)

15

 

(381)

16 

1

/

4

 

(412)

Electrical 

Case to Case 

Connections

17 

1

/

(436)

74 

3

/

8

 

(1890)

Impact  

Excel

P2X-EP

Bulk Produce

Multi-deck,  2  Display Levels

Dimensions shown as inches and (mm).

NSF Certification

This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for
construction, materials & cleanability.

Summary of Contents for Impact Excel P2X-EP

Page 1: ...de FB 0142780 6 Ft Only A 4W Standard Fan Assembly 1 0392457 Fan Motor Evaporator MO 4410101 0382383 Fan Blade FB 4780617 4W Energy Efficient Fan Assembly 1 0477653 Fan Motor Evaporator MO 4410544 038...

Page 2: ...al legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70...

Page 3: ...Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lbs P2X EP 4 ft 6 ft 8 ft 2 7 12 ft 3 9 This is an average for all refrigerant types actual refrigerant charge may vary...

Page 4: ...0Hz Energy Efficient 0 30 0 32 0 40 0 50 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting T 8 fluorescent 1 Row Canopy 0 26 0 51 0 51...

Page 5: ...m3 m ARI Total Display Area 3 Sq Ft Ft 3 39 ft2 ft 1 03 m2 m Shelf Area 4 Sq Ft Ft 3 87 ft2 ft 1 18 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2...

Page 6: ...Canopy Optional Three Row Canopy Connector 4 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band 3 Row Canopy 4 3 4 4 Connector W B BL BL R BL R R R B 4 ft 6 ft or 8 f...

Page 7: ...FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for...

Page 8: ...6 6 R BL R BL R BL 6 6 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground an...

Page 9: ...L R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNI...

Reviews: