4 of 9
P2X-EP
Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact
Excel
P2X-EP
Bulk Produce
Electrical Data
4 ft
6 ft
8 ft
12 ft
Number of Fans—7W
1
—
2
3
Number of Fans—4W
—
2
—
—
Amperes
Watts
4 ft
6 ft
8 ft
12 ft
4 ft
6 ft
8 ft
12 ft
Evaporator Fan
120V
60Hz
Standard
0.50
0.62
1.00
1.50
39
48
78
117
120V
50Hz
Standard
0.55
0.76
1.10
1.65
42
54
84
126
230V
60Hz
Export
0.25
0.30
0.50
0.75
39
48
78
117
230V
50Hz
Export
0.28
0.36
0.56
0.84
42
54
84
126
120V
60Hz
Energy Efficient
0.19
0.24
0.38
0.57
14
16
28
42
230V
60Hz
Energy Efficient
0.10
0.12
0.20
0.30
14
16
28
42
Minimum Circuit Ampacity
120V
60Hz
Standard
0.70
0.82
1.20
1.70
120V
50Hz
Standard
0.75
0.96
1.30
1.85
230V
60Hz
Export
0.45
0.50
0.70
0.95
230V
50Hz
Export
0.48
0.56
0.76
1.04
120V
60Hz
Energy Efficient
0.39
0.44
0.58
0.77
230V
60Hz
Energy Efficient
0.30
0.32
0.40
0.50
Maximum Over Current Protection 120V
20
20
20
20
Maximum Over Current Protection 230V
15
15
15
15
Standard Lighting (T-8 fluorescent)
1 Row Canopy
0.26
0.51
0.51
0.77
30
59
59
85
Optional Lighting (T-8 fluorescent)
Additional 1 Row Canopy
0.26
0.51
0.51
0.77
30
59
59
85
Additional 2 Row Canopy
0.51
1.02
1.02
1.54
59
118
118
170
Additional 3 Row Canopy
0.77
1.53
1.53
2.31
89
177
177
255
1 Row Rail Light
0.26
0.51
0.51
0.77
30
59
59
85
Optional Shelf Lighting (T-8 fluorescent)
1 Row of Shelves
0.26
0.51
0.51
0.77
30
59
59
85
2 Rows of Shelves
0.51
1.02
1.02
1.54
59
118
118
170
3 Rows of Shelves
0.77
1.53
1.53
2.31
59
177
177
255
Optional Always*Bright LED Lighting
1 Row of Shelves
0.15
0.19
0.26
0.38
18
23
31
45
2 Rows of Shelves
0.26
0.34
0.47
0.67
31
41
56
80
3 Rows of Shelves
0.38
0.53
0.74
1.11
45
63
89
133
120V Lighting Circuit Total = Standard Li Total Optional Li Optional Shelf Lighting
230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52