background image

6 of 9

P2X-EP 

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

Refrigeration 

Thermostat

2

To 
Condensing 
Unit

}

Light Blue

1, 2 & 3 Fans

120V N

EUTRAL

B

ROWN

  B

AND

120V P

OWER

Fans

1

B

ROWN

  B

AND

 

 1 Fan 

 

 2 Fans 

 

 2 Fans 

 

 3 Fans

4 ft 
6 ft 
8 ft 

12 ft

12 ft

4

4

3

3

3

4

4

4

4

4

4

Optional 

Two Row 

Canopy

Optional 

Three Row 

Canopy

Connector

4

BL

W

BL

W

G

R

BL

W

B

R

R

R

BL

BL

R

BL

R

R

R

BL

BL

R

BL

R

R

R

B

B

Orange or Tan Band

 

 

                                      3 Row Canopy

4

3

4

4

Connector

W

B

BL

BL

R

BL

R

R

R

B

4 ft

6 ft or 8 ft

12 ft

4 ft

6 ft or 8 ft

12 ft

 

 

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

=  F

IELD

 G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

=  C

ASE

 G

ROUND

Fan Wiring
Offtime Defrost

Light Circuits

Summary of Contents for Impact Excel P2X-EP

Page 1: ...de FB 0142780 6 Ft Only A 4W Standard Fan Assembly 1 0392457 Fan Motor Evaporator MO 4410101 0382383 Fan Blade FB 4780617 4W Energy Efficient Fan Assembly 1 0477653 Fan Motor Evaporator MO 4410544 038...

Page 2: ...al legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70...

Page 3: ...Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lbs P2X EP 4 ft 6 ft 8 ft 2 7 12 ft 3 9 This is an average for all refrigerant types actual refrigerant charge may vary...

Page 4: ...0Hz Energy Efficient 0 30 0 32 0 40 0 50 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting T 8 fluorescent 1 Row Canopy 0 26 0 51 0 51...

Page 5: ...m3 m ARI Total Display Area 3 Sq Ft Ft 3 39 ft2 ft 1 03 m2 m Shelf Area 4 Sq Ft Ft 3 87 ft2 ft 1 18 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2...

Page 6: ...Canopy Optional Three Row Canopy Connector 4 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band 3 Row Canopy 4 3 4 4 Connector W B BL BL R BL R R R B 4 ft 6 ft or 8 f...

Page 7: ...FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for...

Page 8: ...6 6 R BL R BL R BL 6 6 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground an...

Page 9: ...L R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNI...