3 of 8
P/N 0424383_C
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Engineering
Plan Views
Dimensions shown as inches and (mm).
B
C
72
1/4 (1835)
Elec.
Waste Outlet
9
5
/8
(245)
4
(102)
38
7/8
(987)
29
1/4
(743)
30
5/8
(778)
Refrig.
Water Seal
(see note)
34
5/8
(880)
9
(229)
A
46
1/2
(1181)
27
1/2
(699)
Front
F2XLG
4 ft
6 ft
8 ft
12 ft
General
(A)
Case Length
(without ends or partitions)
48
1
/
4
(1226)
72
1
/
4
(1835)
96
3
/
8
(2448)
144
1
/
2
(3670)
(Each end and insulated partition adds 1
1
/
2
in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper)
46
1
/
2
(1181)
46
1
/
2
(1181)
46
1
/
2
(1181)
46
1
/
2
(1181)
Back of case to front of splashguard
38
7
/
8
(987)
38
7
/
8
(987)
38
7
/
8
(987)
38
7
/
8
(987)
Back of case to O/S edge of front skidrail
29
1
/
4
(743)
29
1
/
4
(743)
29
1
/
4
(743)
29
1
/
4
(743)
Width of skidrail
2
1
/
8
(54)
2
1
/
8
(54)
2
1
/
8
(54)
2
1
/
8
(54)
Stub-up area between front skidrail and splashguard
9
5
/
8
(245)
9
5
/
8
(245)
9
5
/
8
(245)
9
5
/
8
(245)
Electrical Service
(Electrical Field Wiring connection point)
(B)
RH End of case to center of farthest knockout
40
1
/
4
(1022)
64
1
/
4
(1632)
88
3
/
8
(2245)
138
7
/
8
(3527)
Back O/S of case to center of knockout
34
5
/
8
(880)
34
5
/
8
(880)
34
5
/
8
(880)
34
5
/
8
(880)
Waste Outlets
(One each end)
(C)
RH End of case to center of waste outlet
24
1
/
8
(613)
24
1
/
8
(613)
24
1
/
8
(613)
72
1
/
4
(1835)
LH End of case to center of waste outlet
24
1
/
8
(613)
48
1
/
8
(1222)
72
1
/
4
(1835)
72
1
/
4
(1835)
Back O/S of case to center of waste outlets
27
1
/
2
(699)
27
1
/
2
(699)
27
1
/
2
(699)
27
1
/
2
(699)
Edge of water seal to center of waste outlet
4 (102)
4 (102)
4 (102)
4 (102)
O/S diameter of drip pipe lines
1
1
/
2
(38)
1
1
/
2
(38)
1
1
/
2
(38)
1
1
/
2
(38)
Note:
Water seal outlet must clear front skid rail. F2 water seal rotation in forward direction only, due to low base.
Refrigeration Outlet
Back O/S of case to center of refrigeration outlet
30
5
/
8
(778)
30
5
/
8
(778)
30
5
/
8
(778)
30
5
/
8
(778)
RH end of case to center of refrigeration outlet
9 (229)
9 (229)
9 (229)
9 (229)