background image

4 of 8

F2XLG  Technical Data Sheet 

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

F2XLG

FAN

26

 1/4 

(667)

28

(711)

(

Optional

)

(727)

(254)

10

18

(406)

55

(1397)

5

 

3

/

16

(136)

27

 

1

/

2 (699)

32

1/

4

(819)

4

 

1

/

4

(108)

29

 

1

/

4 (743)

30

  

 

5

/

8 (778)

34

 

5/8 (879)

FAN

C
O

 L

28

 5/8

38

  

 

7

/

8 (986)

(1182)

46

 

1

/

2

(244)

9

 

5

/

8

16

1/

2

(419)

14 

1/4 

(362)

6

 

(152)

Multideck,  3  Display Levels

Impact  

F2XLG 

Frozen Meat/Seafood

Short Term  Display

Dimensions are shown as inches & (mm).

REFRIGERATION DATA

Note: 

This data is based on store

temperature and humidity that does not
exceed 75

°

F and 55% R.H.

F2XLG

Discharge Air (°F)

-2

Evaporator (°F)

-16

Unit Sizing (°F)

-19

Btu/hr/ft

Parallel

2050

Conventional

2250

DEFROST DATA

F2XLG

Frequency (hr)

6

Defrost Water 

(lb/ft/day)

11.0

(± 15% 

based on case configuration and

product loading).

D

EFROST

E

LECTRIC

Temp Term (°F)

48°

Failsafe (min)  

60

D

EFROST

G

AS

Duration (min)  

18

O

FFTIME

Temp Term (°F)

NA

Failsafe (min)

NA

CONVENTIONAL CONTROLS

Low Pressure Backup Control

CI/CO

*

-23°F / -33°F

Indoor Unit Only, Pressure Defrost
Termination (Temp °F)

NA

*Use a Temperature Pressure Chart to
determine PSIG conversions.

PHYSICAL DATA

Merchandiser

F2XLG

Drip Pipe (in.)

1 1/2

Liquid Line (in.)

3/8

Suction Line (in.)

1 1/8

Estimated Charge (lb)**
4 ft 

1.75

6 ft 

2.53

8 ft 

3.51

12 ft 

5.07

**

This is an average for all refrigerant

types. Actual refrigerant charge may vary
by approximately half a pound.

Length Added to Lineup by:
Each End/Partition (in.)

1 1/2

NSF Certification

These merchandisers are manufactured to meet ANSI /National 
Sanitation Foundation (NSF ®) Standard #7 requirements. 

Summary of Contents for Impact F2XLG

Page 1: ...DA 1 800 922 1919 MEXICO 1 800 522 1900 WWW HUSSMANN COM Note Changed items have been underlined We reserve the right to change or revise specifications and product design in connection with any featu...

Page 2: ...LASTS E 0466234 Ballast 2 lamps 5 BA 4480823 0376410 Ballast 3 lamps BA 4480901 F Fluorescent Lamp 6 Replace with like fixtures Item Part Description Wiring Item HEATERS G 0344662 Heater Limit Thermos...

Page 3: ...en front skidrail and splashguard 9 5 8 245 9 5 8 245 9 5 8 245 9 5 8 245 Electrical Service Electrical Field Wiring connection point B RH End of case to center of farthest knockout 40 1 4 1022 64 1 4...

Page 4: ...G Frequency hr 6 Defrost Water lb ft day 11 0 15 based on case configuration and product loading DEFROST ELECTRIC Temp Term F 48 Failsafe min 60 DEFROST GAS Duration min 18 OFFTIME Temp Term F NA Fail...

Page 5: ...Heater 0 93 1 40 1 86 2 80 112 168 224 336 Reheat 1 44 2 16 2 88 4 32 173 346 346 519 Cycling Anti sweat Heaters NA NA NA NA NA NA NA NA Total Anti sweat Heaters 2 37 3 56 4 74 7 12 285 428 570 855 Gl...

Page 6: ...120V Power Grayed components in 12 ft models only WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Main Fans 12 ft case...

Page 7: ...ctric Light Circuit 2 1 1 1 2 2 Refrigeration Thermostat Dark Blue Klixon Mounted to Distributor Tube Defrost Terminator 48 Defrost Circuit Heater Limit Thermostat 12 ft Case Only 8 Electric Defrost C...

Page 8: ...eaters Grayed components in 12 ft models only WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS 11 2 Pane Multiglass Glas...