22
1
/
2
(572)
25
5/8 (651)
28
3
/
4
(730)
34
( 8 6 4 )
13
3/
4
(349)
33
3
/
8
(849)
44
5
/
8
(1133)
FA N
11
3
/8
( 2 8 9 )
46
(1168)
Refrig.
Outlet
Elec.
FA
N
DA
O
C O I L
3
5/
8
(92)
7
3/
8
(308)
33
5
/8
(854)
18
1
/
2
(470)
Impact
IEDG1
Delicatessen
Dimensions shown as inches & (mm).
REFRIGERATION DATA
Note:
This data is based on store
temperature and humidity that does not
exceed 75
°
F and 55% R.H.
IEDG1
Discharge Air (°F)
24
Evaporator (°F)
14
Unit Sizing (°F)
12
Btu/hr/ft
Parallel
390
Conventional
420
DEFROST DATA
IEDG1
Frequency (hr)
12
Defrost Water (lb/ft/day)
0.20
(± 15%
based on case configuration and
product loading).
O
FFTIME
IEDG1
Temp Term (°F)
43
Failsafe (minutes)
90
E
LECTRIC OR
G
AS
Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
IEDG1
CI/CO*
7°F / -3°F
Cut Out Pressure = Cut In, less 10 PSIG.
Indoor Unit Only, Pressure Defrost
Termination (Temp °F)*
Not Recommended
*Use a Temperature Pressure Chart to
determine PSIG conversions.
PHYSICAL DATA
Merchandiser
IEDG1
Drip Pipe (in.)
1 1/2
Liquid Line (in.)
3/8
Suction Line (in.)
5/8
Estimated Charge (lb)**
8 ft
1.5
12 ft
2.0
**This is an average for all refrigerant
types. Actual refrigerant charge may vary
by approximately half a pound.
Length Added to Lineup by:
Each
Plastic
End w/
Bumper
(in.)
3 1/2
Each End/Partition (in.)
1 1/2
Flat Glass, 1 Display Level
3 of 6
P/N 0431338_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
IEDG1