background image

LWEG 

Technical Data Sheet

2 of 7

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

LWEG

25

 

(635)

Access Area 

(Gray)

12

 3/8 

(314)

Waste 
Outlet

6

 3/4 

(170)

9

 7/8 

(249)

Electrical

Refrig. 
Outlet

43

 

(1092)

43

 

(1092)

81

1/2 

(2071)

6

 1/4 

 

(159)

9

 7/8 

(249)

69

 

(1753)

8

 1/2 

 (214)

12

 1/2 

(318)

Front

32 

3/4

 

(832)

Engineering

Plan Views

Dimensions shown as inches & (mm).

End Case

General

Case Length 

(without ends or partitions)

43 (1092)

(Each end and insulated partition adds 2 in. (51 mm) to case line up.)

Maximum O/S dimension of case back to front 

(includes bumper)

81 

1

/

(2070)

Front of splashguard to O/S edge of front base rail

1

/

(216)

Back of case to O/S edge of front base rail

69 (1753)

Front of case to O/S edge of front base rail

12 

1

/

(318)

Width of base rail

1

/

8

(54)

Stub-up area (gray) between front base rail and splashguard

5

/

(194)

Electrical Service                      

(Electrical Field Wiring connection point)

LH End of case to center of first knockout

3

/

(172)

Back O/S edge of case to nearest knockout

7

/

(251)

Waste Outlets

LH End of case to the center of waste outlet

7

/

(251)

Back O/S of case to center of waste outlet

43 (1092)

Water Seal

Edge of water seal to center of waste outlet

11 (279)

O/S diameter of drip pipe lines

1

/

(38)

Note*: Field installed water seal outlet, tees and connectors are shipped with case.

Refrigeration Outlet

LH end of case to center of front and rear refrigeration outlets

12 

3

/

8

(314)

Front or rear of case to center of front and rear refrigeration outlet

1

/

(83)

Single Deck Frozen Food

Wide Island End

Summary of Contents for IMPACT LWEG

Page 1: ...Modular Electric Defrost Heaters 208V 0406444 6 foot case HE 4850478 6 G Drip Pan Heaters Electric 208V 7 0392412 6 foot case HE 4850461 G Drip Pan Heaters Koolgas 120V 8 0421237 6 foot case HE 485049...

Page 2: ...753 Front of case to O S edge of front base rail 12 1 2 318 Width of base rail 2 1 8 54 Stub up area gray between front base rail and splashguard 7 5 8 194 Electrical Service Electrical Field Wiring c...

Page 3: ...se a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 4 Merchandiser Liquid Line in 3 8 Merchandiser Suction Line in 5 8 Estimated Charge lb End Cas...

Page 4: ...Anti sweat Heaters on fan circuit 120V 60Hz Standard 0 95 114 230V 50Hz Export 0 49 114 Glass Anti sweat Heaters 120V 60Hz Standard 2 08 250 230V 50Hz Export 1 22 280 Cycling Anti sweat Heaters NA 230...

Page 5: ...NEUTRAL BROWN BAND Fan BROWN BAND Nosing anti sweat Heater 1 9 208 V Power From Defrost Contactors L1 L2 Drip Pan Heater Modular Electric Defrost Heater 6 7 Defrost Termination Thermostat Refrigeratio...

Page 6: ...To Condensing Unit Light Blue WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers Grayed components in 12 foot models only...

Page 7: ...White Purple Glass Anti sweat Heater Domestic 2 Pane Multiglass Glass Anti sweat Heater White Black Black 230V Purple 2 Pane Multiglass Glass Anti sweat Heater Black Black White White Glass Anti sweat...

Reviews: