HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
LWU
Technical Data Sheet
4 of 6
Impact
LWU
Frozen Food & Ice Cream
Electrical Data
90 in.
138 in.
Number of Fans – 4W
3
5
(Energy Efficient fan motors are not available for End or End-compartment models)
Amperes
Watts
90 in.
138 in.
90 in.
138 in.
Evaporator Fans
120V
60Hz
Standard
0.93
1.55
72
120
120V
50Hz
Standard
NA
230V
60Hz
Export
0.45
0.75
72
120
230V
50Hz
Export
0.74
1.10
111
165
120V
60Hz
Energy Efficient
0.42
0.70
30
50
230V
60Hz
Energy Efficient
NA
Nosing Anti-sweat Heaters (on fan circuit)
120V
50Hz / 60Hz
1.87
2.83
226
338
230V
50Hz / 60Hz
0.98
1.47
226
338
Cycling Anti-sweat Heaters
120V
50Hz / 60Hz
NA
230V
50Hz / 60Hz
NA
Minimum Circuit Ampacity
120V
60Hz
Standard
3.0
4.58
120V
50Hz
Standard
NA
230V
60Hz
Export
2.63
2.42
230V
50Hz
Export
1.92
2.77
120V
60Hz
Energy Efficient
2.49
3.73
230V
60Hz
Energy Efficient
NA
Maximum Over Current Protection 120V
20
20
Maximum Over Current Protection 230V
15
15
Electric Defrost Heaters
208V
60Hz
Standard Front Compartment
4.00
8.00
835
1670
208V
60Hz
Standard Rear Compartment
4.00
8.00
835
1670
208V
60Hz
Standard End Compartment
5.50
5.50
1150
1150
230V
50Hz
Export Front Compartment
4.40
8.90
1012
2047
230V
50Hz
Export Rear Compartment
4.40
8.90
1012
2047
230V
50Hz
Export End Compartment
6.10
6.10
1403
1403
Koolgas Drip Pan Heaters
120V
60Hz
Standard
3.75
6.25
450
750
230V
50Hz
Export
NA
Standard Lighting:
None