background image

Gas Defrost – Optional

LWUGH 

Technical Data Sheet

6 of 7

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

Refrigeration 

Thermostat

To 
Condensing Unit

}

Light Blue

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded. 

Circled Numbers = Parts List Item Numbers 

Grayed components in 12 foot models only.

(Field Installed)

2

Drip Pan Heater

Yellow

Heater Switch

120V POWER

120V NEUTRAL

Dar

k

 Blue

Dar

k

 Blue

Yellow

8

4

Drip Pan Heater

Yellow

Heater Switch

120V POWER

120V NEUTRAL

Dar

k

 Blue

Dar

k

 Blue

Yellow

8

4

Drip Pan Heater

Yellow

Heater Switch

120V POWER

120V NEUTRAL

Dar

k

 Blue

Dar

k

 Blue

Yellow

8

4

B

ROWN

  B

AND

Fan

B

ROWN

  B

AND

1

9

Nosing (anti-sweat) Heater

B

ROWN

  B

AND

Fans

B

ROWN

  B

AND

Nosing (anti-sweat) Heaters

120V POWER

B

ROWN

  B

AND

Fans

B

ROWN

  B

AND

120V NEUTRAL

1

9

1

9

Nosing (anti-sweat) Heaters

Summary of Contents for IMPACT LWUGH

Page 1: ...oolgas 120V 8 0421237 90 inch case HE 4850495 0421238 138 inch case HE 4850496 0421237 End Compartment HE 4850495 H Nosing Anti sweat Heaters Discharge 9 0401603 90 inch case Front Rear HE 4850470 040...

Page 2: ...1 2 64 2 1 2 64 Stub up area gray between front base rail and splashguard 7 5 8 194 7 5 8 194 Electrical Service Electrical Field Wiring connection point Edge of case to center of knockouts 6 3 4 172...

Page 3: ...Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 4 Merchandiser Liquid Line in 3 8 Merchandiser Suction Line in 7 8 Estimated Charge lb 90 in 2 8 138 in 4 6 Thi...

Page 4: ...2 86 3 56 329 413 230V 50Hz Export 1 58 1 98 363 455 Cycling Anti sweat Heaters 120V 50Hz 60Hz NA 230V 50Hz 60Hz NA Minimum Circuit Ampacity 120V 60Hz Standard 5 86 8 14 120V 50Hz Standard NA 230V 60...

Page 5: ...ntactors L1 L2 Modular Electric Defrost Heaters Drip Pan Heater Modular Electric Defrost Heaters Drip Pan Heater WARNING All components must have mechanical ground and the merchandiser must be grounde...

Page 6: ...n 12 foot models only Field Installed 2 Drip Pan Heater Yellow Heater Switch 120V POWER 120V NEUTRAL Dark Blue Dark Blue Yellow 8 4 Drip Pan Heater Yellow Heater Switch 120V POWER 120V NEUTRAL Dark Bl...

Page 7: ...hite Black Black 230V Purple 2 Pane Multiglass Glass Anti sweat Heater Black Black White White Glass Anti sweat Heater Export Only LWUGH 90 LWUGH 138 Unitized LWUGH 90 LWUGH 138 Unitized WARNING All c...

Reviews: