background image

Control

Panel

Access

B

E

D

F

Condensing

Unit

Access

G

H

I

C

J

A

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

P/N 0480307

Note:  

Changed items have been underlined.

Merchandisers

®

Item

Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES AND

T

HERMOSTATS

A.

6W

Fan Assembly

(1)

0058698

Fan Motor, Evaporator

0382383

Fan Blade
embossing toward motor

B.

0382028

Standard Non-adjustable 

(2)

Thermostat

H

EATERS

C.

0314573

Evaporator Pan Heater

(3)

Item

Part #

Description

Wiring Item #

C

ONTROL

P

ANEL

D.

0047449

Defrost Timer

(4)

E.

0019187

Disconnect Switch

(5)

F.

0394263

Pressure Control

(6)

R

EFRIGERATION

G.

0424716

Condensing Unit Assembly 

H.

0381050

TEV

I.

0331344

Sight Glass

J.

0111482

Drier

L

AMPS AND

B

ALLASTS

None

M1CIMP-4B

Data Sheet Set

P/N 0480307

November  2005

We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.

Summary of Contents for IMPACT M1CIMP-4B

Page 1: ...73 Evaporator Pan Heater 3 Item Part Description Wiring Item CONTROL PANEL D 0047449 Defrost Timer 4 E 0019187 Disconnect Switch 5 F 0394263 Pressure Control 6 REFRIGERATION G 0424716 Condensing Unit Assembly H 0381050 TEV I 0331344 Sight Glass J 0111482 Drier LAMPS AND BALLASTS None M1CIMP 4B Data Sheet Set P N 0480307 November 2005 We reserve the right to change or revise specifications and prod...

Page 2: ...8 1185 2 3 4 70 23 584 29 7 8 759 35 7 8 911 C L M1CIMP 4B 10 2005 55 1 4 1403 51 1 4 1302 4 ft 6 ft 8 ft 12 ft General A Case Length Note Includes One Pair Ends 53 3 8 1357 Optional End Bumpers One Pair 2 51 Maximum O S dimension of case back to front 46 5 8 1357 Note Includes bumper Back of case to front of splashguard 35 7 8 911 Center of rear Wheel to center of front Wheel 23 694 Waste Outlet ...

Page 3: ...en 33 F CONVENTIONALCONTROLS Low Pressure Backup Control M1CIMP 4B CI CO 14 F 8 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 5 8 Refrigeration Charge lbs 4 ft M1CIMP 4B R 22 3 5 3 of 6 HUSSMANN CORPORATION Bridgeton MO 63044 2483 U S A P N 0480307 ...

Page 4: ...s Watts 4 ft 4 ft ft Merchandiser Fans Standard 120V 60Hz 0 46 39 Export 230V 50Hz NA NA Energy Efficient 120V 60Hz NA NA Evaporator Pan Heater 120V 8 4 Minimum Circuit Ampacity With Standard Fans 120V 60Hz 17 73 Export 230V 50Hz NA With Energy Efficient Fans 120V 60Hz NA Maximum Over Current Protection 120V 25 Standard Lighting None Optional Lighting None Optional Shelf Lighting None ...

Page 5: ...Box Blue Start Capacitor Current Relay S M L 3 1 Red Black White Current Relay Timer Switch Thermostat 120 Volt Condenser Heater Evaporator Fan 3 5 Pressure Control 115 1 60 Power Supply 1 2 6 4 Self Contained Wiring Diagram 120V POWER 120V NEUTRAL WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS ...

Page 6: ...ck panel retainers and save mounting screws 3 Install new lower back panel retainers P N 073418 using saved screws 4 Mount upper back panel as shown using 4 screws provided 5 Mount lower back panel P N 0473717 by sliding up and under upper panel until stopped by 1 8 in offset on upper back panel 6 Align slots in bottom flange of lower back panel with retainers Lower panel and allow it to rest atop...