background image

REFRIGERATION DATA

Note: 

This data is based on store temperature

and humidity that does not exceed 75

°

F and

55% R.H. 

M1CIMP-4B

Discharge Air °F

26

Evaporator °F

18

Unit Sizing °F

16

DEFROST DATA

M1CIMP-4B

Frequency (hr)

6

Defrost Water (lb/ft/day)

2

(±15% based on case configuration and prod-

uct loading.)

O

FFTIME

M1CIMP-4B

Temp Term °F

43°F

Failsafe Minutes

35

E

LECTRIC OR

G

AS

Not Recommended

Standard Defrost Thermostat

Close on rise:    close 43°F — open 33°F

CONVENTIONAL CONTROLS

Low Pressure Backup Control

M1CIMP-4B

CI/CO**

14°F / 8°F

Indoor Unit Only, Pressure Defrost

Termination**

48°F

**Use a Temperature Pressure Chart to

determine PSIG conversions.

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

2

Liquid Line (in.)

3

/

8

Suction Line (in.)

5

/

8

Refrigeration Charge (lbs)

4 ft

M1CIMP-4B

R-22

3.5

3 of 6

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

P/N 0480307

13 

3

/

8

(340)

39 

1

/

4

(997)

22 

3

/

8

(568)

30

(762)

46 

5

/

8

(1185)

34 

1

/

8

(867)

35 

7

/

8  

(911)

23

  

(584)

Impact  

M1CIMP-4B

Meat/Delicatessen

Precut & Packaged Produce

Self-Contained Single Deck, 1 Display Level, Wood Clad

Dimensions shown as inches and (mm).

M1CIMP-4B

Summary of Contents for IMPACT M1CIMP-4B

Page 1: ...73 Evaporator Pan Heater 3 Item Part Description Wiring Item CONTROL PANEL D 0047449 Defrost Timer 4 E 0019187 Disconnect Switch 5 F 0394263 Pressure Control 6 REFRIGERATION G 0424716 Condensing Unit Assembly H 0381050 TEV I 0331344 Sight Glass J 0111482 Drier LAMPS AND BALLASTS None M1CIMP 4B Data Sheet Set P N 0480307 November 2005 We reserve the right to change or revise specifications and prod...

Page 2: ...8 1185 2 3 4 70 23 584 29 7 8 759 35 7 8 911 C L M1CIMP 4B 10 2005 55 1 4 1403 51 1 4 1302 4 ft 6 ft 8 ft 12 ft General A Case Length Note Includes One Pair Ends 53 3 8 1357 Optional End Bumpers One Pair 2 51 Maximum O S dimension of case back to front 46 5 8 1357 Note Includes bumper Back of case to front of splashguard 35 7 8 911 Center of rear Wheel to center of front Wheel 23 694 Waste Outlet ...

Page 3: ...en 33 F CONVENTIONALCONTROLS Low Pressure Backup Control M1CIMP 4B CI CO 14 F 8 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 5 8 Refrigeration Charge lbs 4 ft M1CIMP 4B R 22 3 5 3 of 6 HUSSMANN CORPORATION Bridgeton MO 63044 2483 U S A P N 0480307 ...

Page 4: ...s Watts 4 ft 4 ft ft Merchandiser Fans Standard 120V 60Hz 0 46 39 Export 230V 50Hz NA NA Energy Efficient 120V 60Hz NA NA Evaporator Pan Heater 120V 8 4 Minimum Circuit Ampacity With Standard Fans 120V 60Hz 17 73 Export 230V 50Hz NA With Energy Efficient Fans 120V 60Hz NA Maximum Over Current Protection 120V 25 Standard Lighting None Optional Lighting None Optional Shelf Lighting None ...

Page 5: ...Box Blue Start Capacitor Current Relay S M L 3 1 Red Black White Current Relay Timer Switch Thermostat 120 Volt Condenser Heater Evaporator Fan 3 5 Pressure Control 115 1 60 Power Supply 1 2 6 4 Self Contained Wiring Diagram 120V POWER 120V NEUTRAL WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS ...

Page 6: ...ck panel retainers and save mounting screws 3 Install new lower back panel retainers P N 073418 using saved screws 4 Mount upper back panel as shown using 4 screws provided 5 Mount lower back panel P N 0473717 by sliding up and under upper panel until stopped by 1 8 in offset on upper back panel 6 Align slots in bottom flange of lower back panel with retainers Lower panel and allow it to rest atop...

Reviews: