background image

4 of 4

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

M1DE Data Sheet

Impact  

M1DE

Meat/Delicatessen
Precut & Packaged Produce

Electrical Data

8 ft

12 ft

Number of Fans — 6W

2

3

Amperes

Watts

8 ft

12 ft

8 ft

12 ft

Merchandiser

Fans

Standard (120V 60Hz)

1.00

1.50

78

117

Export (230V 50Hz)

0.56

0.84

88

132

Energy Efficient (120V 60Hz)

0.52

0.78

36

54

Minimum Circuit Ampacity

With Standard Fans (120V 60Hz)

1.20

1.70

Export (230V 50Hz)

0.76

1.04

With Energy Efficient Fans (120V 60Hz)

0.72

0.98

Maximum Over Current Protection 120V

20

20

Maximum Over Current Protection 230V

15

15

Supplemental Gas Heaters

NA

208V 1

Φ

Φ

Electric Defrost 

NA

Standard Lighting

Optional Lighting

Optional Shelf Lighting

None

None

None

Defrost

Termination

Thermostat

2

To
Condensing
Unit

}

Dark Blue

=  120V P

OWER

=  120V N

EUTRAL

WARNING

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS                    

G

RAYED 

C

OMPONENTS 

I

12

 

F

OOT 

M

ODELS 

O

NLY.    

Fan  Wiring
Offtime Defrost

2 & 3 Fans

120V N

EUTRAL

B

ROWN

  B

AND

120V P

OWER

Fans

1

B

ROWN

  B

AND

Light Blue

3

Refrigeration

Thermostat

Reviews: