8 Ft
12 ft
General
(A)
Length of Case
(without ends or partitions)
96
3
/
8
(2448)
144
1
/
2
(3670)
Maximum outside dimensions of case back to front
(includes bumper)
40
1
/
2
(1030)
40
1
/
2
(1030)
Back of case to front of splashguard
33
1
/
2
(851)
33
1
/
2
(851)
Back of case to outside edge of front skidrail
29
1
/
2
(749)
29
1
/
2
(749)
Width of skidrail
4
1
/
2
(114)
4
1
/
2
(114)
Stub-up area between front skidrail and splashguard
4 (102)
4 (102)
Electrical Service
(B)
Right end of case to center of farthest knockout
88
3
/
8
(2245)
136
1
/
2
(3467)
Back outside of case to center of knockout
31 (787)
31 (787)
Length of electrical raceway
34
1
/
2
(878)
34
1
/
2
(878)
*Note:
Electrical Field Wiring Connection Point
Waste Outlet
(C)
Right end of case to center of waste outlet
24
1
/
8
(613)
72
1
/
4
(1835)
Left end of case to center of waste outlet
72
1
/
4
(1835)
72
1
/
4
(1835)
Back outside of case to center of waste outlet
27 (686)
27 (686)
Water Seal
Edge of water seal to center of waste outlet
4 (102)
4 (102)
Outside diameter of drip pipe
1
1
/
2
(38)
1
1
/
2
(38)
*
Note:
Water seal outlet must clear front skid rail.
Refrigeration Outlet
Right end of case to center of refrigeration outlet
9 (230)
9 (230)
Back outside of case to center of refrigeration outlet
27
1
/
2
(699)
27
1
/
2
(699)
2 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
M4NGE
Data Sheet
4
(102)
9
(230)
27
1/2
(699)
27
(686)
B
C
Skid/ External Base
A
72
1/4 (1835)
4
3/8 (111)
Refrigeration
Outlet
Waste Outlet
Water Seal
Elec.
31
(787)
Access Area
40
1/2
(1030)
Front
(See Note*)
29
1/2
(749)
33
1/2
(851)
Dimensions shown as inches and (mm).
Engineering
Plan View
Narrow