6
1
/
2
(165)
P1X49MOB-B
29
7
/
8
(760)
30
3
/
8
(773)
34
7
/
8
(883)
46
1
/
4
(1174)
16
3
/
4
(425)
49
3
/
4
(1263)
25
1
/
2
(648)
17
3
/
8
(441)
16
1
/
2
(420)
F
A
N
C
O
I
L
3
/
16
(5)
REFRIGERATION DATA
Note:
This data is based on store temperature
and humidity that does not exceed 75°F and
55% R.H. Schedule defrost at night while
lights are off.
P1X49MOB-B
Discharge Air °F
31
Evaporator °F
24
Unit Sizing °F
22
Btu/hr/case
594
DEFROST DATA
P1X49MOB-B
Frequency (hr)
8
Defrost Water (lb/ft/day)
NA
(±15% based on case configuration and
product loading.)
O
FFTIME
P1X49MOB-B
Temp Term °F
43°F
Failsafe Minutes
35
E
LECTRIC OR
G
AS
Not Recommended
Standard Defrost Thermostat
Close on rise: close 43°F — open 33°F
CONVENTIONALCONTROLS
Low Pressure Backup Control
P1X49MOB-B
CI/CO**
14 / 4°F
Indoor Unit Only, Pressure Defrost
Termination**
48°F
**Use a Temperature Pressure Chart to deter-
mine PSIG conversions.
PHYSICAL DATA
Drip Pipe (in.)
1
1
/
2
Liquid Line (in.)
3
/
8
Suction Line (in.)
5
/
8
Estimated Charge (lbs)***
P1X49MOB-B
6 ft
3.6
8 ft
4.0
***This is an average for all refrigerant types
actual refrigerant charge may vary by approx-
imately half a pound.
Length (in.) Added to Lineup by Each
End or Insulated Partition
1
1
/
2
Impact
P1X49MOB-B
Bulk Produce, Self-Contained
Single Deck, 49 Inch High Back, 1 Display Level
Mobile Self-Contained
Dimensions shown as inches and (mm).
3 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P/N 0457222