background image

2 of 6

P2 Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

Electrical

Refrigeration

72 

1

/

4

 (1835)

1

/

8

 (105)

24 

1

/

8

 (613)

1

/

2

 (140)

3

/

8

 (35)

1

/

2

 (114)

29 

1

/

2

(749)

35 

1

/

8

(891)

46 

1

/

4

(

1174)

9

(230)

30 

5

/

8

(778)

27 

1

/

2

(699)

40 

5

/

8

(1032)

4 (102)

Water Seal

(See Note*)

Waste Outlet

4

 

(102)

40 

5

/

8

(1032)

30 

1

/

2

(775)

96 

3

/

8

 (2448)

88 

3

/

8

 (2245)

Dimensions shown as inches and (mm).

8 Ft

12 ft

General

Length of Case (without ends or partitions)

96 

3

/

8

(2448)

144 

1

/

2

(3670)

Maximum outside dimensions of case back to front (includes bumper)

46 

1

/

4

(1174)

46 

1

/

4

(1174)

Back of case to front of splashguard

35 

1

/

(891)

35 

1

/

(891)

Back of case to outside edge of front skidrail

29 

1

/

(749)

29 

1

/

(749)

Width of skidrail

1

/

(114)

1

/

(114)

Right end of case to outside edge of external support

1

/

(140)

1

/

(140)

Distance between inside edges of external support and center support

40 

5

/

(1032)

40 

5

/

(1032)

Distance between inside edges of center supports

NA

44 (1118)

Width of external support

1

/

(105)

1

/

(105)

Stub-up area between front skidrail and splashguard

4 (102)

4 (102)

Right edge of case (excluding end) to inside edge of external support

3

/

(35)

3

/

(35)

Electrical Service

Right end of case to center of farthest knockout

88 

3

/

(2245)

136 

1

/

(3467)

Back outside of case to center of knockout

30 

1

/

(775)

30 

1

/

(775)

Length of electrical raceway

34 

1

/

(876)

34 

1

/

(876)

Waste Outlet

Right end of case to center of waste outlet

24 

1

/

(613)

72 

1

/

(1835)

Left end of case to center of waste outlet

72 

1

/

(1835)

72 

1

/

(1835)

Back outside of case to center of waste outlet

27 

1

/

(699)

27 

1

/

(699)

Water Seal

Edge of water seal to center of waste outlet

4 (102)

4 (102)

Outside diameter of drip pipe

1

/

(38)

1

/

(38)

*

Note:

Water seal outlet must clear front skid rail.

Refrigeration Outlet

Right end of case to center of refrigeration outlet

9 (230)

9 (230)

Back outside of case to center of refrigeration outlet

30 

5

/

(778)

30 

5

/

(778)

Engineering

Plan Views

Produce

12-2003

Summary of Contents for Impact P2

Page 1: ...ing toward motor B 0411744 Standard Non adjustable 2 Thermostat C 0137880 Optional Adjustable 3 Refrigeration Thermostat Note Changed items have been underlined Merchandisers D E B D C E A P2 Data Sheet Set P N 0378424B NSF Certified December 2003 Item Part Description Wiring Item LAMPS AND BALLASTS D 0428648 Ballast 2 lamps 4 D 0428649 Ballast 3 lamps 4 E Fluorescent Lamp 5 Replace with like fixt...

Page 2: ...0 5 8 1032 Distance between inside edges of center supports NA 44 1118 Width of external support 4 1 8 105 4 1 8 105 Stub up area between front skidrail and splashguard 4 102 4 102 Right edge of case excluding end to inside edge of external support 1 3 8 35 1 3 8 35 Electrical Service Right end of case to center of farthest knockout 88 3 8 2245 136 1 2 3467 Back outside of case to center of knocko...

Page 3: ...TIME P2 P2E Temp Term F 48 F 48 F Failsafe Minutes 30 30 ELECTRIC OR GAS Not Recommended Standard Defrost Thermostat Close on rise close 48 F open 33 F CONVENTIONALCONTROLS Low Pressure Backup Control P2 P2E CI CO 14 4 F 17 7 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Liquid Line ...

Page 4: ... 56 0 84 88 132 Energy Efficient 120V 60Hz 0 52 0 78 36 54 Constant on Anti sweat Heaters NA Cycling Anti sweat Heaters NA Min Circuit Ampacity With Standard Fans 120V 60Hz 1 20 1 70 Export 230V 50Hz 0 76 1 04 With Energy Efficient Fans 120V 60Hz 0 72 0 98 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Supplemental Gas Heaters NA 208V 1Φ Φ Electric Defrost NA...

Page 5: ... Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shel...

Page 6: ...0V NEUTRAL Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White Optional Lighting 1 Row Rail 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL R R R BL BL 4 BL R R R BL BL 4 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R R BL BL 4 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER O...

Reviews: