4 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P4 Data Sheet
Impact
P4
Bulk Produce
Electrical Data
8 Ft
12 Ft
Number of Fans — 6W
2
3
Amperes
Watts
Merchandiser
8 Ft
12 Ft
8 Ft
12 Ft
Fans
Standard (120V 60Hz)
2.80
4.20
210
320
Export (230V 50Hz)
1.52
2.28
228
342
Energy Efficient (120V 60Hz)
1.52
2.28
100
150
Constant on Anti-sweat Heaters
NA
Cycling Anti-sweat Heaters
NA
Min. Circuit Ampacity
With Standard Fans (120V 60Hz)
3.00
4.40
Export (230V 50Hz)
1.72
2.48
With Energy Efficient Fans (120V 60Hz)
1.72
2.48
Maximum Over Current Protection 120V
20
20
Maximum Over Current Protection 230V
15
15
Supplemental Gas Heaters
NA
208V 1
Φ
Φ
Electric Defrost
NA
Standard Lighting
1 Row Canopy
0.51
0.77
59
85
Optional Lighting
1 Row Canopy and 1 Rail
1.02
1.54
118
170
2 Rows Canopy
1.02
1.54
118
170
2 Rows Canopy and 1 Row Rail
1.53
2.31
177
255
Optional Shelf Lighting
1 Row of Shelves
0.51
0.77
59
85
2 Rows of Shelves
1.02
1.54
118
170
3 Rows of Shelves
1.53
2.31
177
255