HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

P/N 0415128A

Note: 

Changed items have been underlined.

Merchandisers

®

D

B

E

C

E

A

D

E

P4NE

Data Sheet Set

P/N 0415128A

NSF

®

Certified

August  2004

Item Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES AND

T

HERMOSTATS

A.

9W

Fan Assembly

(1)

0047000

Fan Motor, Evaporator 

0141070

Fan Blade
embossing toward motor

B. 0411744

Standard Non-adjustable

(2)

Defrost Thermostat

C. 0137880

Optional Adjustable 

(3)

Refrigeration Thermostat

Item Part #

Description

Wiring Item #

L

AMPS AND

B

ALLASTS

D. 0428648

Ballast, Electronic

2 lamps

(4)

D. 0428649

Ballast, Electronic

3 lamps

(4)

E.

Fluorescent Lamp

(5)

Replace with like fixtures

We reserve the right to change
or revise specifications and
product design in connection
with any feature of our 
products. Such changes 
do not entitle the buyer to 
corresponding changes,
improvements, additions or
replacements for equipment
previously sold or shipped.

Summary of Contents for IMPACT P4NE

Page 1: ...411744 Standard Non adjustable 2 Defrost Thermostat C 0137880 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0428648 Ballast Electronic 2 lamps 4 D 0428649 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace with like fixtures We reserve the right to change or revise specifications and product design in connection with any feature of our...

Page 2: ...external support 4 1 8 105 4 1 8 105 Stub up area between front skidrail and splashguard 3 76 3 76 Right edge of case excluding end to inside edge of external support 1 3 8 35 1 3 8 35 Electrical Service B Right end of case to center of farthest knockout 88 3 8 2245 136 1 2 3467 Back outside of case to center of knockout 31 787 31 787 Length of electrical raceway 34 1 2 878 34 1 2 878 Note Electri...

Page 3: ...rost Water lb ft day 8 15 based on case configuration and product loading OFFTIME P4NE Temp Term F 48 F Failsafe Minutes 30 ELECTRIC OR GAS Not Recommended Standard Defrost Thermostat Close on rise close 48 F open 33 F CONVENTIONAL CONTROLS Low Pressure Backup Control CI CO 17 F 7 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions PH...

Page 4: ...s 120V 60Hz 1 60 2 30 With Energy Efficient Fans 120V 60Hz 0 96 1 34 Export 230V 50Hz 0 96 1 34 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Supplemental Gas Heaters NA 208V 1Φ Φ Electric Defrost NA Standard Lighting 1 Row Canopy 0 51 0 77 59 85 Optional Lighting 1 Row Canopy and 1 Rail 1 02 1 54 118 170 2 Rows Canopy 1 02 1 54 118 170 2 Rows Canopy and 1 R...

Page 5: ...ll components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G R 5 4 W BL R 5 BL R G R R ...

Page 6: ...ed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Optional Lighting 1 Row Rail 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 120V NEUTRAL ORANGE OR TAN BAND Light Sw...