2 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P4NE
Data Sheet
Front Base Rail
A
72
1
/
4 (1835)
4
3
/
8
(111)
Refrigeration
Outlet
Waste Outlet
Water Seal
9
(230)
Electrical
31
(787)
Access Area
40
5
/
8
(1030)
2 7
(686)
Front
2 7
1
/
2
(699)
(see note*)
29
1
/
2
(749)
33
1
/
2
(851)
3
(076)
4 (102)
B
C
Dimensions shown as inches and (mm).
8 Ft
12 ft
General
(A)
Length of Case
(without ends or partitions)
96
3
/
8
(2448)
144
1
/
2
(3670)
Maximum outside dimensions of case back to front
(includes bumper)
40
5
/
8
(1030)
40
5
/
8
(1030)
Back of case to front of splashguard
33
1
/
2
(851)
33
1
/
2
(851)
Back of case to outside edge of front skidrail
29
1
/
2
(749)
29
1
/
2
(749)
Width of skidrail
2
1
/
8
(54)
2
1
/
8
(54)
Distance between inside edges of external support and center support
40
5
/
8
(1032)
40
5
/
8
(1032)
Distance between inside edges of center supports
NA
44 (1118)
Width of external support
4
1
/
8
(105)
4
1
/
8
(105)
Stub-up area between front skidrail and splashguard
3 (76)
3 (76)
Right edge of case (excluding end) to inside edge of external support
1
3
/
8
(35)
1
3
/
8
(35)
Electrical Service
(B)
Right end of case to center of farthest knockout
88
3
/
8
(2245)
136
1
/
2
(3467)
Back outside of case to center of knockout
31 (787)
31 (787)
Length of electrical raceway
34
1
/
2
(878)
34
1
/
2
(878)
*Note:
Electrical Field Wiring Connection Point
Waste Outlet
(C)
Right end of case to center of waste outlet
24
1
/
8
(613)
72
1
/
4
(1835)
Left end of case to center of waste outlet
72
1
/
4
(1835)
72
1
/
4
(1835)
Back outside of case to center of waste outlet
27 (686)
27 (686)
Water Seal
Edge of water seal to center of waste outlet
4 (102)
4 (102)
Outside diameter of drip pipe
1
1
/
2
(38)
1
1
/
2
(38)
**
Note:
Water seal outlet must clear front skid rail.
Refrigeration Outlet
Right end of case to center of refrigeration outlet
9 (230)
9 (230)
Back outside of case to center of refrigeration outlet
27
1
/
2
(699)
27
1
/
2
(699)
Engineering
Plan View
P4NE
All Produce