background image

P/N 0415128A

3 of 6

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

12

 

1

/

2

(317)

P4NE

C

O

I

L

FAN

 

3

 1/8

(079)

3/

8

(111)

Refrigeration
Outlet

Ligh

ted S

helf

(Opti

onal

)

6

 1/2 (165)

(Optional)

Ligh

ted S

helf

(Opti

onal

)

3

  

(76)

 

7

 

1

/

2

(191)

31  

(787)

14

(

356

)

(321

)

27

 

1

/

2  

(699)

29

 

1

/

2  

(749)

24

 

1

/

2

(662)

(968)

38

 

1

/

8

81

 

1

/

8

(2061

)

12 

 

5

/

8

(1245)

49

(1356)

16

(

406)

53

 

3

/

8

27  

(686)

25

 

3

/

8

(668)

21

 

1

/

2

(546)

33

 

1

/

2  

(851)

40

 

5

/

8  

(1030)

REFRIGERATION DATA

Note:

This data is based on store temperature

and humidity that does not exceed 75°F and
55% R.H.

P4NE

Discharge Air °F

31

Evaporator °F

24

Unit Sizing °F

22

Btu/hr/ft**

P4NE

Parallel

1630

Conventional

1745

**For all refrigeration equipment other than
Husssmann, use conventional BTU values.

DEFROST DATA

P4NE

Frequency (hr)

6

Defrost Water (lb/ft/day)

8

(±15% based on case configuration and
product loading.

O

FFTIME

P4NE

Temp Term °F

48°F

Failsafe Minutes

30

E

LECTRIC OR

G

AS

Not Recommended

Standard Defrost Thermostat

Close on rise: close 48°F – open 33°F

CONVENTIONAL CONTROLS

Low Pressure Backup Control
CI/CO**

17°F / 7°F

Indoor Unit Only, Pressure Defrost
Termination**

48°F

**Use a Temperature Pressure Chart to
determine PSIG conversions.

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

2

Liquid Line (in.)

3

/

8

Suction Line (in.)

7

/

8

Estimated Charge (lbs)***

P4NE

8 ft

3.2

12 ft

4.5

***This is an average for all refrigerant types
actual refrigerant charge may vary by
approximately half a pound.

Length Added to Lineup by Each End
or Insulated Partition (in.)

1

/

2

Impact 

P4NE

All Produce

Multi-deck, 4 Display Levels

Dimensions shown as inches and (mm).

NSF Certification

These merchandisers are manufactured to meet ANSI /National 
Sanitation Foundation (NSF

®

) Standard #7 requirements. 

Summary of Contents for IMPACT P4NE

Page 1: ...411744 Standard Non adjustable 2 Defrost Thermostat C 0137880 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0428648 Ballast Electronic 2 lamps 4 D 0428649 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace with like fixtures We reserve the right to change or revise specifications and product design in connection with any feature of our...

Page 2: ...external support 4 1 8 105 4 1 8 105 Stub up area between front skidrail and splashguard 3 76 3 76 Right edge of case excluding end to inside edge of external support 1 3 8 35 1 3 8 35 Electrical Service B Right end of case to center of farthest knockout 88 3 8 2245 136 1 2 3467 Back outside of case to center of knockout 31 787 31 787 Length of electrical raceway 34 1 2 878 34 1 2 878 Note Electri...

Page 3: ...rost Water lb ft day 8 15 based on case configuration and product loading OFFTIME P4NE Temp Term F 48 F Failsafe Minutes 30 ELECTRIC OR GAS Not Recommended Standard Defrost Thermostat Close on rise close 48 F open 33 F CONVENTIONAL CONTROLS Low Pressure Backup Control CI CO 17 F 7 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions PH...

Page 4: ...s 120V 60Hz 1 60 2 30 With Energy Efficient Fans 120V 60Hz 0 96 1 34 Export 230V 50Hz 0 96 1 34 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Supplemental Gas Heaters NA 208V 1Φ Φ Electric Defrost NA Standard Lighting 1 Row Canopy 0 51 0 77 59 85 Optional Lighting 1 Row Canopy and 1 Rail 1 02 1 54 118 170 2 Rows Canopy 1 02 1 54 118 170 2 Rows Canopy and 1 R...

Page 5: ...ll components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G R 5 4 W BL R 5 BL R G R R ...

Page 6: ...ed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Optional Lighting 1 Row Rail 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 120V NEUTRAL ORANGE OR TAN BAND Light Sw...

Reviews: