background image

4 of 6

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

P4NE 

Data Sheet

Impact  

P4NE

All Produce

Electrical Data

8 Ft

12 Ft

Number of Fans — 9W

2

3

Amperes

Watts

Merchandiser

8 Ft

12 Ft

8 Ft

12 Ft

Fans

Standard (120V 60Hz)

1.40

2.10

100

150

Energy Efficient (120V 60Hz)

0.76

1.14

50

75

Export (230V 50Hz)

0.76

1.14

114

171

Cycling Anti-sweat Heaters

NA

Minimum Circuit Ampacity

With Standard Fans (120V 60Hz)

1.60

2.30

With Energy Efficient Fans (120V 60Hz)

0.96

1.34

Export (230V 50Hz)

0.96

1.34

Maximum Over Current Protection 120V

20

20

Maximum Over Current Protection 230V

15

15

Supplemental Gas Heaters

NA

208V 1

Φ

Φ

Electric Defrost

NA

Standard Lighting

1 Row Canopy

0.51

0.77

59

85

Optional Lighting

1 Row Canopy and 1 Rail

1.02

1.54

118

170

2 Rows Canopy

1.02

1.54

118

170

2 Rows Canopy and 1 Row Rail

1.53

2.31

177

255

Optional Shelf Lighting

1 Row of Shelves

0.51

0.77

59

85

2 Rows of Shelves

1.02

1.54

118

170

3 Rows of Shelves

1.53

2.31

177

255

4 Rows of Shelves

2.04

3.08

236

340

Summary of Contents for IMPACT P4NE

Page 1: ...411744 Standard Non adjustable 2 Defrost Thermostat C 0137880 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0428648 Ballast Electronic 2 lamps 4 D 0428649 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace with like fixtures We reserve the right to change or revise specifications and product design in connection with any feature of our...

Page 2: ...external support 4 1 8 105 4 1 8 105 Stub up area between front skidrail and splashguard 3 76 3 76 Right edge of case excluding end to inside edge of external support 1 3 8 35 1 3 8 35 Electrical Service B Right end of case to center of farthest knockout 88 3 8 2245 136 1 2 3467 Back outside of case to center of knockout 31 787 31 787 Length of electrical raceway 34 1 2 878 34 1 2 878 Note Electri...

Page 3: ...rost Water lb ft day 8 15 based on case configuration and product loading OFFTIME P4NE Temp Term F 48 F Failsafe Minutes 30 ELECTRIC OR GAS Not Recommended Standard Defrost Thermostat Close on rise close 48 F open 33 F CONVENTIONAL CONTROLS Low Pressure Backup Control CI CO 17 F 7 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions PH...

Page 4: ...s 120V 60Hz 1 60 2 30 With Energy Efficient Fans 120V 60Hz 0 96 1 34 Export 230V 50Hz 0 96 1 34 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Supplemental Gas Heaters NA 208V 1Φ Φ Electric Defrost NA Standard Lighting 1 Row Canopy 0 51 0 77 59 85 Optional Lighting 1 Row Canopy and 1 Rail 1 02 1 54 118 170 2 Rows Canopy 1 02 1 54 118 170 2 Rows Canopy and 1 R...

Page 5: ...ll components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G R 5 4 W BL R 5 BL R G R R ...

Page 6: ...ed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Optional Lighting 1 Row Rail 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 120V NEUTRAL ORANGE OR TAN BAND Light Sw...

Reviews: