background image

PWWSP49 

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

4 of 4

Impact  

PWWSP49

All Produce

Electrical Data

Number of Fans

4 ft

6 ft

8 ft

12 ft

Refrigeration — 9W

2

4

4

6

Refrigeration — 9W (Export)

NA

Amperes

Watts

Merchandiser

4 ft

6 ft

8 ft

12 ft

4 ft

6 ft

8 ft

12 ft

Fans (Refrigeration)

Standard (120V 60Hz)

1.4

2.8

2.8

4.2

110

220

220

330

Energy Efficient (120V 60Hz)

NA

Export (230V 50 Hz)

NA

Minimum Circuit Ampacity

With Standard Fans (120V 60Hz)

1.6

3.0

3.0

4.4

With Energy Efficient Fans (120V 60Hz)

NA

With Export Fans (230V 50 Hz)

NA

Maximum Over Current Protection 120V

20

20

20

20

Maximum Over Current Protection 230V

NA

Standard Lighting

Optional Lighting

Optional Shelf Lighting

None

None

None

=  120V P

OWER

=  120V N

EUTRAL

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded. 

Circled Numbers = Parts List Item Numbers 

Grayed components in 12 foot models only.

Fan  Wiring 
Offtime Defrost

B

ROWN

  B

AND

Fans

B

ROWN

  B

AND

120V POWER

120V NEUTRAL

1

2, 4 or 6 

Fans

4 ft case has 2 Fans 
6 ft case has 4 Fans 
8 ft case has 4 Fans 

12 ft case has 6 Fans

 

B

ROWN

  B

AND

Fans

B

ROWN

  B

AND

1

Summary of Contents for Impact PWWSP49

Page 1: ...0103 0141070 Fan Blade FB 0141070 Embossing toward motor 2007 HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A U S CANADA 1 800 922 1919 MEXICO 1 800 522 1900 WWW HUSSMANN COM We reserve the right to change or revise specifications and product design in connection with any feature of our products Such changes do not entitle the buyer to corresponding changes improvements additions or replacement...

Page 2: ... waste outlet 4 102 4 102 4 102 4 102 Center of waste outlet to outside edge of front base rail 3 1 2 89 3 1 2 89 3 1 2 89 3 1 2 89 Note Field installed water seal outlets tees and connectors are shipped with case Drip Pipe Outlet D Left end of case to center of drip pipe outlet 20 3 8 517 19 1 2 495 19 1 2 495 68 1 2 1740 E Center of waste outlet to center of drip pipe outlet 3 3 4 95 24 3 4 629 ...

Page 3: ...7 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 11 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb PWWSP49 4 ft 2 7 6 ft 4 4 8 ft 5 4 12 ft 7 8 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound Length Added to Lineup ...

Page 4: ... 60Hz 1 6 3 0 3 0 4 4 With Energy Efficient Fans 120V 60Hz NA With Export Fans 230V 50 Hz NA Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V NA Standard Lighting Optional Lighting Optional Shelf Lighting None None None 120V POWER 120V NEUTRAL WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Ite...