RLNI with
Innovator Doors
Technical Data Sheet
2 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
5
3
/
8
(142)
Refrig. Outlet
A
C
B
Front Relay & Terminal
Block Location
Front
5-Door Shown
6
(152)
(see note *)
Water Seal (see note **)
63
1
/
8
(1603)
67
7
/
8
(1724)
72
1
/
4
(1835)
60
1
/
2
(1537)
Electrical Wireway
70
1
/
8
(1780)
Bottom Front
Support
48
(1219)
3
(76)
4
(102)
Waste Outlet
Skid/External Base
Reach-in Narrow Island
2, 3, 4, & 5 Door
08/2002
Engineering Plan Views
RLNI
Plan View
Electrical Wireway
3
(76)
4
(102)
D
Refrig. Outlet
Rear Relay & Terminal Block Location
Dimensions shown as in. & (mm).
Serial Plate attached to top left front of each case.
2 Dr
3 Dr
4 Dr
5 Dr
General
(A)
Case Length
(without ends or partitions)
62 (1575)
92
1
/
2
(2350)
122
7
/
8
(3121) 153
3
/
8
(3896)
Maximum O/S dimension of case back to front
72
1
/
4
(1835)
72
1
/
4
(1835)
72
1
/
4
(1835)
72
1
/
4
(1835)
(Includes bumper)
Back of case to rear of splashguard
67
7
/
8
(1724)
67
7
/
8
(1724)
67
7
/
8
(1724)
67
7
/
8
(1724)
Width of Skidrail
4
1
/
2
(114)
4
1
/
2
(114)
4
1
/
2
(114)
4
1
/
2
(114)
Width of Bottom Front Support
6 (152)
6 (152)
6 (152)
6 (152)
Stub-up area between front skidrail and splashguard
6
3
/
8
(1000)
6
3
/
8
(1000)
6
3
/
8
(1000)
6
3
/
8
(1000)
Electrical Service
RH end of case to the center of nearest knockout
4 (102)
4 (102)
4 (102)
4 (102)
(B)
RH end of case to the center of LH knockout
58 (1473)
88
1
/
2
(2248)
118
7
/
8
(3019) 149
3
/
8
(3794)
Back O/S of case to center of knockout
70
1
/
8
(1780)
70
1
/
8
(1780)
70
1
/
8
(1780)
70
1
/
8
(1780)
* NOTE: Electrical Field Wiring Connection Point is at terminal.
Waste Outlet
(C)
Right end of case to center of waste outlet
23
3
/
4
(603)
54
1
/
4
(1378)
46
1
/
4
(1175)
76
5
/
8
(1946)
Back O/S of case to center of waste outlet
63
1
/
8
(1603)
63
1
/
8
(1603)
63
1
/
8
(1603)
63
1
/
8
(1603)
Water Seal
Edge of water seal to center of waste outlet
11 (279)
11 (279)
11 (279)
11 (279)
Outside diameter of drip piping
1
1
/
4
(32)
1
1
/
4
(32)
1
1
/
4
(32)
1
1
/
4
(32)
** NOTE: Field installed water seal outlets, tees, and connectors are shipped with case
Refrigeration Outlet
RH end of case to center of RH refrigeration outlet
5
3
/
8
(137)
5
3
/
8
(137)
5
3
/
8
(137)
5
3
/
8
(137)
Back O/S of case to center of refrigeration outlet
60
1
/
2
(1537)
60
1
/
2
(1537)
60
1
/
2
(1537)
60
1
/
2
(1537)
(D)
Outside bottom front supports from end of case
6
3
/
4
(170)
6
3
/
4
(170)
6
3
/
4
(170)
6
3
/
4
(170)
Center bottom front support from Centerline
24 (610)
24 (610)
24 (610)
24 (610)
Distance between Center and Outside supports will vary
01-2003