RLNI with
Innovator Doors
Technical Data Sheet
4 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Electrical Data
2Dr
3Dr
4Dr
5Dr
Number of Fans—12W
2
3
4
5
Amperes
Watts
Merchandiser
2Dr
3Dr
4Dr
5Dr
2Dr
3Dr
4Dr
5Dr
Evaporator Fan
120V
60Hz
Standard
1.30
1.95
2.60
3.25
100
150
200
250
120V
50Hz
Standard
1.50
2.25
3.00
3.75
114
171
228
285
220V
60Hz
Export
0.66
0.99
1.32
1.65
100
150
200
250
220V
50Hz
Export
0.76
1.14
1.52
1.90
114
171
228
285
120V
60Hz
Energy Efficient
0.60
0.90
1.20
1.50
36
54
72
90
220V
60Hz
Energy Efficient
0.30
0.45
0.60
0.75
36
54
72
90
Door Anti-sweat Heaters (on fan circuit)
120V
50/60Hz Standard
1.54
2.31
3.08
3.86
185
278
370
463
220V
50/60Hz Export
0.84
1.26
1.68
2.10
185
278
370
463
Frame Anti-sweat Heaters (on fan circuit)
120V
50/60Hz Standard
0.78
1.18
1.57
1.97
94
141
188
236
220V
50/60Hz Export
0.43
0.64
0.85
1.07
94
141
188
236
Minimum Circuit Ampacity
120V
60Hz
Standard
3.82
5.64
7.45
9.28
120V
50Hz
Standard
4.02
5.94
7.85
9.78
220V
60Hz
Export
2.13
3.09
4.05
5.02
220V
50Hz
Export
2.23
3.24
4.25
5.27
120V
60Hz
Energy Efficient
3.12
4.59
6.05
7.53
220V
60Hz
Energy Efficient
1.77
2.55
3.33
4.12
Maximum Over Current Protection 120V
20
20
20
20
Maximum Over Current Protection 220V
15
15
15
15
Defrost
Drain Heaters (120V)
0.63
1.25
2.00
2.57
75
150
240
300
(Export: 220V 50 Hz)
0.34
0.76
1.22
1.53
84
168
269
336
208V 1Ø
Electric Defrost
6.72
10.08
13.46
16.82
1400
2100
2800
3500
(Export: 220V 50 Hz)
7.11
10.66
14.24
17.79
1564
2345
3133
3914
Standard Vertical Lighting
2Dr
3Dr
4Dr
5Dr
2Dr
3Dr
4Dr
5Dr
Innovator* Doors
(120V)
1.50
2.00
2.50
3.00
180
240
300
360
(Export: 220V 50 Hz)
0.84
1.12
1.40
1.68
185
246
308
370
Optional LED Lighting (120V)
0.87
1.16
1.45
1.74
105
140
174
209
*
Innovator
or
Innovator II
ELECTRICAL DATA IS PER SIDE — TWO CIRCUITS REQUIRED PER CASE.
Hussmann recommends against frame heater cycling with
Innovator doors to prevent door seals from freezing to the
frames and tearing.
Impact
RLNI
With INNOVATOR Doors
Frozen Food & Ice Cream