background image

2 Dr

3 Dr

4 Dr

5 Dr

General

(A)

Case Length (without ends or partitions)

62 (1575)

92 

1

/

2  

(2350)

122 

7

/

8  

(3121) 153 

3

/

(3896)

Maximum outside dimension of case back to front

42 

1

/

8  

(1070)

42 

1

/

8  

(1070)

42 

1

/

8  

(1070)

42 

1

/

8  

(1070)

(Includes bumper)

Back of case to rear of splashguard

39 

3

/

(1000) 39 

3

/

(1000) 39 

3

/

(1000) 39 

3

/

(1000)

Width of Skidrail

1

/

(114)

1

/

(114)

1

/

(114)

1

/

(114)

Width of Bottom Front Support

6 (152)

6 (152)

6 (152)

6 (152)

Stub-up area between front skidrail and splashguard

3

/

(1000)

3

/

(1000)

3

/

(1000)

3

/

(1000)

Electrical Service 

Left hand end of case to the center of nearest knockout

3

/

(70)

3

/

(70)

3

/

(70)

3

/

(70)

(B)

Right hand end of case to the center of center knockout 56 

7

/

8

(1444)

87 

3

/

(2219)

117 

3

/

(2991)

148 

1

/

(3764)

Back outside of case to center of knockout

34 

1

/

(876)

34 

1

/

(876)

34 

1

/

(876)

34 

1

/

(876)

Raceway Length

62 (1575)

62 (1575)

62 (1575)

62 (1575)

*NOTE:

Electrical Field Wiring Connection Point is at terminal.

Waste Outlet

(C)

Right end of case to center of waste outlet

23 

3

/

(603)

54 

1

/

(1378)

46 

1

/

(1175)

76 

5

/

(1946)

Back outside of case to center of waste outlet

34 

1

/

(876)

34 

1

/

(876)

34 

1

/

(876)

34 

1

/

(876)

Water Seal

Edge of water seal to center of waste outlet

11 (279)

11 (279)

11 (279)

11 (279)

Outside diameter of drip piping

1

/

(32)

1

/

(32)

1

/

(32)

1

/

(32)

** NOTE:

Field installed water seal outlets, tees, and connectors are shipped with case.

Refrigeration Outlet

(D)

Righthand end of case to center of righthand
refrigeration outlet

1

/

(184)

1

/

(184)

1

/

(184)

1

/

(184)

Back outside of case to center of refrigeration outlet

3

/

(138)

3

/

(138)

3

/

(138)

3

/

(138)

Outside bottom front supports from end of case

3

/

4

(170)

3

/

4

(170)

3

/

4

(170)

3

/

4

(170) 

Center bottom front support from Centerline

24 (610)

24 (610)

24 (610)

24 (610)

Distance between Center and Outside supports will vary.
Top piping is standard in the RLT case.

RLT with Innovator Doors 

Technical Data Sheet

2 of 6

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

Dimensions shown as inches & (mm).

08-2003

D

3

/

8

(142)

Front

(152)

 

(see note *)

Water Seal

 (see note **)

34

(860)

32

(813)

42

 

1

/

8

(1070)

Refrigeration

Outlet

A

B

C

Bottom Front

Support

Waste Outlet

Relay & Terminal

 Block Location

Skid/External Base

Tall Reach-In

2, 3, 4, & 5 Door

Engineering

Plan Views

48

(1219)

34

 

1

/

2

(876)

62

(1575)

Electrical Wireway

Dimensions shown as inches & (mm).

Reviews: