background image

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

SMGV Data Sheet Set

2 of 6

4 ft

6 ft

8 ft

12 ft

General

(A)

Case Length*

48 

1

/

(1226)

72 

1

/

(1835)

96 

3

/

8

(2448)

144 

1

/

2

(3670)

Maximum O/S dimension of case back to front

44 

5

/

8

(1134)

44 

5

/

8

(1134)

44 

5

/

8

(1134)

44 

5

/

8

(1134)

(Note: Includes bumper)

Back of case to front of splashguard

33 

3

/

8

(848)

33 

3

/

8

(848)

33 

3

/

8

(848)

33 

3

/

8

(848)

Center of rear legs to center of front legs

25 

5

/

8

(651)

25 

5

/

8

(651)

25 

5

/

8

(651)

25 

5

/

8

(651)

Each End and Partition adds 1 

1

/

2

in. (38 mm) to the length of the lineup.

Electrical Service 

(B)

RH end of case to Electrical raceway right edge

7 (178)

7 (178)

7 (178)

7 (178)

(C)

RH end of case to Electrical raceway left edge

41 

3

/

8

(1051)

32 

3

/

4

(831)

44 

1

/

2

(1131)

44 

1

/

2

(1131)

Back of case to center of knockout

5

/

8

(92)

5

/

8

(92)

5

/

8

(92)

5

/

8

(92)

* Electrical Field Wiring Connection Point

Waste Outlet

(D)

RH end of case to the center of waste outlet

24 (610)

24 (610)

24 (610)

24 (610)

Back of case to center of waste outlet

25 

5

/

8

(652)

25 

5

/

8

(652)

25 

5

/

8

(652)

25 

5

/

8

(652)

Water Seal

Center of tee to center of waste outlet

11 

3

/

8

(289)

11 

3

/

8

(289)

11 

3

/

8

(289)

11 

3

/

8

(289)

Outside diameter of drip piping

1

/

2

(38)

1

/

2

(38)

1

/

2

(38)

1

/

2

(38)

** Field installed water seal outlets, tees, and connectors are shipped with the merchandiser.

Refrigeration Outlet

Back of case to center of refrigeration outlet

28 

3

/

4

(731)

28 

3

/

4

(731)

28 

3

/

4

(731)

28 

3

/

4

(731)

(E)

RH end of case to center of refrigeration outlet

3

/

8

(238)

3

/

8

(238)

3

/

8

(238)

3

/

8

(238)

Outside diameter of the liquid line

3

/

8

(9.5)

3

/

8

(9.5)

3

/

8

(9.5)

3

/

8

(9.5)

Outside diameter of the suction line

5

/

8

(16)

5

/

8

(16)

5

/

8

(16)

5

/

8

(16)

Engineering

Plan Views

(See Note*) 

25

 5

/

8

(651)

25

 5

/

8

(651)

Legs

28

 3

/

4

(730)

F r o n t

Refrigeration
Outlet

Water Seal

Waste Outlet

Leg Center Lines

Electrical 

44

 5

/

8

(1133)

33

 3

/

8

(849)

(See Note**) 

SMBV

SMGV

SSGV

A

B

D

C

E

Meat & Delicatessen

Multi-Pane Flat Glass

Models

Dimensions shown as in. and (mm).