lEctrIcal
WIRING COLOR CODE
Standard Case Wire Color Code
Ground
Anti-Sweat
Lights
Receptacles
T-Stat/Solenoid 230VAC
T-Stat/Solenoid 115VAC
T-Stat/Solenoid 24VAC
Fan Motors
Blue Condensing Unit
Green
Purple
Orange
Yellow
Red/Black
White/Black
Red/White
Brown
Use Copper Conductors Only
430-01-0338 R101003
Color Decsription
Color
CASE MUST BE GROUNDED
BEFORE SERVICING
ALWAYS DISCONNECT ELECTRICAL
POWER AT THE MAIN DISCONNECT
WHEN SERVICING OR REPLACING ANY
ELECTRICAL COMPONENT.
This includes (but not limited to) Heaters and Lights.
DANGER
ELECTRICAL CIRCUIT IDENTIFICATION
Standard lighting for all models will be full length
fluorescent lamps located within the case. The switch
controlling the lights is located at the top right of the case.
FIELD WIRING AND SERIAL PLATE
AMPERAGE
Field Wiring must be sized for component amperes
printed on the serial plate. Actual ampere draw may be
less than specified. Most component amperes are listed
in the “Wiring Diagram” section, but always check the
serial plate.
BALLAST LOCATION
Ballasts are located within the access panel that runs
the length of the top of the case
3. Electrical