HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
IM-H 1-13
Hot Merchandiser
ISLA IM-H
6. Electrical Wiring Diagrams
CLEANING PRECAUTIONS
When cleaning:
•
Do not use high pressure water hoses
•
Do not introduce water faster then waste outlet can drain
•
NEVER INTRODUCE WATER ON SELF CONTAINED UNIT
WITH AN EVPORATOR FAN
•
NEVER USE A CLEANING OR SANITIZING SOLUTION
THAT HAS AN OIL BASE (these will dissolve the butyl
sealants) or an AMMONA BASE (this will corrode the
copper components of the case)
•
TO PRESERVE THE ATTRACTIVE FINISH:
•
DO USE WATER AND A MILD DETERGENT FOR THE
EXTERIOR ONLY
•
DO NOT USE A CHLORINATED CLEANER ON ANY
SURFACE
•
DO NOT USE ABRASIVES OR STEEL WOOL SCOURING
PADS (these will mar the finish)
CAUTION
Maintenance (Cont'd)
Fluorescent Lamp Disposal:
The United States Environmental Protection Agency has
information regarding environmentally-safe fluorescent
lamp waste management programs.
On the Net: EPA Website:
http://www.epa.gov/osw/hazard/wastetypes/universal/
lamps/recycle.htm
IM-03-I3-H 208V/240V
3'
W6600037
IM-03-4-H 208V
4'
W6600014
IM-03-I4-H (With 30 AMP cord)
4'
W6600011
IM-03-5-H
5'
W6600028
IM-03-6-H 240V
6'
W6600013
IM-03-6-H 208V
6'
W6600009
IM-03-8-H
8'
W6600039
IM-04-I3-H
4'
W6600061
IM-04-C4-H
4'
W6600001
IM-04-4-H (With 30 AMP cord)
4'
W6600007
IM-04-I5-H 3-PHASE
5'
W6600053
IM-04-E5-H 230/1/60
5'
W6600005
IM-05-I3-H
3'
W6600036
IM-05-E5-H
5'
W6600002
IM-05-C4-H
4'
W6600004
IM-05-C4-H (With 30 AMP cord)
4'
W6600006
IM-05-C4-H 3-PHASE
4'
W6600045
IM-04
IM-04-I6-H
6'
W6600012
IM-05
IM-05-C6-H
6'
W6600003
ISLA HOT
IM-03
IM-04
IM-05
Fluorescent Lamp Disposal:
The United States Envi-
ronmental protection Agency has information regarding
environmentally-safe fluorescent lamp waste manage-
ment programs.
On the Net: EPA Web site:
http://www.epa.gov/osw/hazard/wastetypes/universal/lam
ps/recycle.htm
CAUTION
Fluorescent Lamps contain mercury
vapor. Mercury exposure at hih levels can
harm the brain, heart, kidneys, lungs and
immune system of people of all ages. Do
not break or puncture flourescent lamps.
Dispose of, or store, all flourescent lamps
in accordance with Federal (40 CFR
273), State and local hazardous waste
requirements. Refer to
http://www.epa.gov/mercury/about.htm
continued from previous page....
6. RINSE, RINSE, RINSE
If chlorinated cleaners are used you must rinse,
rinse, rinse and wipe dry immediately. The sooner
you wipe off standing water, especially when it
contains cleaning agents, the better. After wiping the
equipment down, allow it to air dry, as oxygen helps
maintain the stainless steel’s passivity film.
7. Never Use Hydrochloric Acid (Muriatic Acid) on
Stainless Steel