background image

REFRIGERATION DATA

Note: 

This data is based on store temperature and

humidity that does not exceed 75

°

F and 55% R.H. 

M1XD-E

Discharge Air (°F)

27

Evaporator (°F)

18

Unit Sizing (°F)

16

Btu/hr/ft

M1XD-E

Parallel

495

Conventional

530

DEFROST DATA

M1XD-E

Frequency (hr)

6

Defrost Water (lb/ft/day)

2

(± 15% 

based on case configuration and

product loading).

O

FF

T

IME

M1XD-E

Temp Term 

(

°

F

)

43

°

F

Failsafe (minutes)

35

E

LECTRIC OR

G

AS

Not Recommended 

Standard Defrost Thermostat 

Close on rise: close 43°F  —  open 33°F 

CONVENTIONAL CONTROLS

Low Pressure Backup Control

M1XD-E

CI/CO

*

11°F / 1°F

Indoor Unit Only, Pressure Defrost

Termination*

48°F

*Use a Temperature Pressure Chart to

determine PSIG conversions.

Estimated Charge (lb)**

M1XD-E

4 ft 

0.9

6 ft 

1.2

8 ft 

1.7

12 ft 

2.3

**This is an average for all refrigerant types.

Actual refrigerant charge may vary by

approximately half a pound.

3 of 5

P/N 0477071_C

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

31 

5

/

(804)

3

/

4  

(120)

30 

1

/

4   

(768)

42 

 

(1064)

33 

1

/

(851)

26 

1

/

(665)

Electrical 

Case to Case 

Connections

FAN

L

3 In. 

(77 mm) 

Required 

Air Gap

Refrigeration 
Outlet

28 

5

/

8

 

(727)

31

 

(787)

11

 

(280)

17 

1

/

(436)

12 

1

/

(311)

5

/

8  

(194)

3

/

(246)

39 

1

/

8

 

(994)

30 

1

/

4   

(766)

1

/

(54)

3

/

(222)

1

/

8   

(232)

Dimensions shown as inches and (mm).

Single Deck, 1 Display Level

Impact  

Excel

M1XD-E

Meat, Delicatessen 

Pre-cut and Packaged Produce

M1XD-E

NSF Certification

This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for
construction, materials & cleanability.

Reviews: