Electrical Data

4 ft

6 ft

8 ft

12 ft

Number of Fans—9W

1

2

2

3

Amperes

Watts

4 ft

6 ft

8 ft

12 ft

4 ft

6 ft

8 ft

12 ft

Evaporator Fan

120V

60Hz

Standard

0.24

0.48

0.48

0.72

25

50

50

75

120V

50Hz

Standard

0.27

0.54

0.54

0.81

28

56

56

84

Minimum Circuit Ampacity

120V

60Hz

Standard

0.44

0.68

0.68

0.92

120V

50Hz

Standard

0.47

0.74

0.74

1.01

Maximum Over Current Protection 120V

20

20

20

20

Maximum Over Current Protection 230V

15

15

15

15

Nosing Anti-sweat Heaters

120V

50Hz/60Hz

Standard

0.40

0.50

0.80

1.00

48

60

96

120

Return Glass Anti-sweat Heaters

120V

50Hz/60Hz

Standard

0.26

0.50

0.52

0.78

23

60

46

69

208V 

Electric Defrost

3.3

4.8

6.6

9.9

685

990

1370

2055

120V

KoolGas Defrost

NA

Standard Lighting

None

Optional Lighting

None

Optional Shelf Lighting

None

4 of 6

M1XLD-GE 

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Impact  

Excel 

M1XLD-GE

Frozen Meat and Delicatessen

NA

NA

NA

Summary of Contents for M1XLD-GE

Page 1: ...iring Item FAN ASSEMBLIES AND THERMOSTATS A 9W Standard Fan Assembly 1 0440420 Fan Motor Evaporator MO 4410302 0376413 Fan Blade FB 0376413 0123592 Relay DPDT 208V coil 4 RL 4440495 0253603 Relay DPDT...

Page 2: ...f external legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70...

Page 3: ...E 4 ft 0 9 6 ft NA 8 ft 1 7 12 ft 2 3 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound 3 of 7 P N 0490770_B HUSSMANN CORPORATION BRIDGETON...

Page 4: ...rent Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Nosing Anti sweat Heaters 120V 50Hz 60Hz Standard 0 40 0 50 0 80 1 00 48 60 96 120 Return Glass Anti sweat Heaters 120...

Page 5: ...Cu Ft Ft 1 93 ft3 ft 0 18 m3 m ARI Total Display Area 3 Sq Ft Ft 2 57 ft2 ft 0 78 m2 m Shelf Area 4 Sq Ft Ft 2 51 ft2 ft 0 76 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft...

Page 6: ...y 1 Blue WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers Grayed components in 12 foot models only R Red 120V POWER Fron...

Page 7: ...t Timer 120V Only Blue L3 Yellow Relay 1 WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers Grayed components in 12 foot m...