background image

M4EP

LUS

Data Sheet

6 of 6

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

Standard Lighting  1 Row Canopy  or Optional 1 Row Rail

Light Circuits

Optional  Lighting  2 Rows Canopy

WARNING

All components must have mechanical ground, and the merchandiser must be grounded.

=  120V P

OWER

=  120V N

EUTRAL

Grayed components in 12 foot models only.

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

Optional  Lighting  3 Row Canopy

120V N

EUTRAL

O

RANGE

 

OR

 T

AN

 B

AND

W

Light

Switch

120V P

OWER

O

RANGE

 

OR

 T

AN

B

AND

B

B

W

4

BL

R

R

BL

BL

3

BL

R

R

BL

BL

3

4

120V N

EUTRAL

O

RANGE

 

OR

 T

AN

 B

AND

W

Light

Switch

120V P

OWER

O

RANGE

 

OR

 T

AN

B

AND

B

BL

R

R

BL

BL

3

4

4

120V N

EUTRAL

O

RANGE

 

OR

 T

AN

 B

AND

W

Light

Switch

120V P

OWER

O

RANGE

 

OR

 T

AN

B

AND

B

B

W

BL

R

R

BL

BL

3

BL

R

R

BL

BL

3

W

B

BL

R

R

BL

BL

3

R

4

R

R

R

R

R

4

4

4

4

4

4

4

4

4

4

4

4

4

Summary of Contents for M4EP

Page 1: ...e embossing toward motor C 0137880 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0428648 Ballast Electronic 2 lamps 4 D 0428649 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace with like fixtures We reserve the right to change or revise specifications and product design in connection with any feature of our products Such changes do n...

Page 2: ...e between inside edges of center supports NA 44 1118 Width of external support 4 1 8 105 4 1 8 105 Stub up area between front skidrail and splashguard 4 102 4 102 Right edge of case excluding end to inside edge of external support 1 3 8 35 1 3 8 35 Electrical Service Electrical Field Wiring connection point B Right end of case to center of farthest knockout 88 3 8 2245 136 1 2 3467 Back outside of...

Page 3: ...rge Air F 31 29 Evaporator F 28 26 Unit Sizing F 26 24 Btu hr ft M4EPLUS UNLIT LIT Parallel 1095 1185 Conventional 1190 1290 For all refrigeration equipment other than Hussmann use conventional Btu values DEFROST DATA Frequency Hrs 6 Defrost Water lb ft day 8 15 based on case configuration and product loading OFFTIME M4EPLUS Time minutes 30 ELECTRIC OR GAS Not Recommended CONVENTIONALCONTROLS Low ...

Page 4: ... Fans 120V 60Hz 3 00 4 40 Export 230V 50Hz 1 72 2 48 With Energy Efficient Fans 120V 60Hz 1 72 2 48 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Supplemental Gas Heaters NA 208V 1Φ Φ Electric Defrost NA Standard Lighting 1 Row Canopy 0 51 0 77 59 85 Optional Lighting 1 Row Canopy and 1 Rail 1 02 1 54 118 170 2 Row Canopy 1 02 1 54 118 170 2 Row Canopy and 1...

Page 5: ...ve mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 4 6 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light...

Page 6: ...ot models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Optional Lighting 3 Row Canopy 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W 4 BL R R BL BL 3 BL R R BL BL 3 4 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 3 4 4 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V ...