background image

6 of 9

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A

.

M4NX-GEP 

Technical Data  Sheet

4

4

3

3

3

4

4

4

4

4

4

Optional 

Two Row 

Canopy

Optional 

Three Row 

Canopy

Connector

4

BL

W

BL

W

G

R

BL

W

B

R

R

R

BL

BL

R

BL

R

R

R

BL

BL

R

BL

R

R

R

B

B

Orange or Tan Band

 

 

                                      3 Row Canopy

B

4 ft

6 ft or 8 ft

12 ft

 

 

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

=  F

IELD

 G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

=  C

ASE

 G

ROUND

Refrigeration 

Thermostat

2

To 
Condensing 
Unit

}

Light Blue

1, 2 & 3 Fans

120V N

EUTRAL

B

ROWN

  B

AND

120V P

OWER

Fans

1

B

ROWN

  B

AND

 

 1 Fan 

 

 2 Fans 

 

 2 Fans 

 

 3 Fans

4 ft 
6 ft 
8 ft 

12 ft

12 ft

Fan Wiring
Offtime Defrost

Light Circuits

Summary of Contents for M4NX-GEP

Page 1: ...4780446 6 Ft Only A 7W Standard Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0461805 Fan Blade FB 4780446 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0461805...

Page 2: ...Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electrical Service Electrical Field Wiring connection point...

Page 3: ...nit Sizing F 26 24 Btu hr ft Unlit Shelves M4NX GEP Parallel Conventional UNLIT 1045 1155 Add 10 Btu hr ft per shelf row for LED fixtures Add 20 Btu hr ft per shelf row for fluorescent lamps DEFROST D...

Page 4: ...59 59 85 Optional Lighting T 8 fluorescent Additional 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Additional 2 Row Canopy 0 51 1 02 1 02 1 54 59 118 118 170 Additional 3 Row Canopy 0 77 1 53 1 53 2...

Page 5: ...lay Area 3 Sq Ft Ft 3 69 ft2 ft 1 13 m2 m Shelf Area 4 Sq Ft Ft 5 60 ft2 ft 1 71 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refrigerated V...

Page 6: ...B 4 ft 6 ft or 8 ft 12 ft R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded...

Page 7: ...G All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Four Rows of Shelve...

Page 8: ...L 6 6 R BL R BL R BL 6 6 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground a...

Page 9: ...L R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNI...

Reviews: