background image

Wireway

Splashguard

26 

3

/

(680)

25 

1

/

(641)

37

 

(940)

A

41 

1

/

(1054)

28 

1

/

(724)

3 In. 

(77 mm)

 

Required 

Air Gap

Refrigeration 

Outlet

Waste Outlet

Waste Outlet

FRONT

3

/

(120)

21 

1

/

(540)

D

C

8

 

(203)

12 

1

/

(307)

1

/

(108)

41 

1

/

(1054)

43 

7

/

(1114)

B

19

 

(483)

NOTE: Case-to-Case Electrical Connections 
are made IN FRONT OF SPLASHGUARD. 

Electrical 

Stub Up Area 

6 x 6 

(152x152)

 

Electrical 
Field 
Connection

26 

1

/

(673)

3

/

(120)

1

/

(115)

4 ft

6 ft

8 ft

12 ft

General

(A)

Case Length 

(without ends or partitions)

48 

3

/

8

(1229)

72 

3

/

8

(1838)

96 

3

/

8

(2448)

144 

1

/

2

(3670)

(Each end and insulated partition adds 1 

1

/

in. (38 mm) to case line up.)

Maximum O/S dimension of case back to front 

(includes bumper)

37 (940)

37 (940)

37 (940)

37 (940)

Back of case to front of splashguard

28 

1

/

(724)

28 

1

/

(724)

28 

1

/

(724)

28 

1

/

(724)

Back of case to O/S edge of front leg

25 

1

/

(641)

25 

1

/

(641)

25 

1

/

(641)

25 

1

/

(641)

Distance between edges of external legs and center legs

NA

29 

1

/

(750)

41 

1

/

(1054)

41 

1

/

(1054)

Distance between edges of center legs

NA

NA

NA

43 

7

/

(1114)

Distance between front legs and splashguard

3

/

4

(70)

3

/

4

(70)

3

/

4

(70)

3

/

4

(70)

Electrical Service             

(Electrical Field Wiring connection point)

(B)

RH End of case to center of stub up area

36 

1

/

(921)

60 

1

/

(1530)

84 

1

/

(2140)

132 

3

/

(3363)

Back of case to center of stub up area

19 (483)

19 (483)

19 (483)

19 (483)

Length of electrical wireway

26 

1

/

(673)

26 

1

/

(673)

26 

1

/

(673)

26 

1

/

(673)

(C)

RH End of case to LH end of wireway

42 

1

/

(1070)

66 

1

/

(1680)

90 

1

/

(2289)

138 

1

/

(3511)

Waste Outlets  

(One each end)

(D)

RH End of case to the center of LH waste outlet

36 

1

/

(921)

60 

1

/

(1530)

84 

1

/

(2140)

132 

3

/

(3363)

RH End of case to the center of RH waste outlet

12 

1

/

(307)

12 

1

/

(307)

12 

1

/

(307)

12 

1

/

(307)

Back O/S of case to center of waste outlets

26 

3

/

(680)

26 

3

/

(680)

26 

3

/

(680)

26 

3

/

(680)

Schedule 40 PVC drip pipe

1

/

(32)

1

/

(32)

1

/

(32)

1

/

(32)

Refrigeration Outlet

Back of case to center of refrigeration outlet

21 

1

/

(540)

21 

1

/

(540)

21 

1

/

(540)

21 

1

/

(540)

RH end of case to center of refrigeration outlet

8  (203)

8  (203)

8  (203)

8  (203)

2 of 9

M5NX-GEP

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Engineering

Plan Views

Dimensions shown as inches and (mm).

Meat / Delicatessen

10-2004

M5NX

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

4

Merchandiser Liquid Line (in.)

3

/

8

Merchandiser Suction Line (in.)

7

/

8

Wireway

Summary of Contents for M5NX-GEP

Page 1: ...4780446 6 Ft Only A 7W Standard Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780...

Page 2: ...0 2 3 4 70 2 3 4 70 2 3 4 70 Electrical Service Electrical Field Wiring connection point B RH End of case to center of stub up area 36 1 4 921 60 1 4 1530 84 1 4 2140 132 3 8 3363 Back of case to cent...

Page 3: ...determine PSIG conversions Estimated Charge lb M5NX GEP 4 ft 1 9 6 ft 2 5 8 ft 3 7 12 ft 5 1 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a po...

Page 4: ...ing T 8 fluorescent Additional 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Additional 2 Row Canopy 0 51 1 02 1 02 1 54 59 118 118 170 Additional 3 Row Canopy 0 77 1 53 1 53 2 31 89 177 177 255 1 Row...

Page 5: ...lay Area 3 Sq Ft Ft 4 28 ft2 ft 1 30 m2 m Shelf Area 4 Sq Ft Ft 6 94 ft2 ft 2 12 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refrigerated V...

Page 6: ...3 3 4 4 4 4 4 4 Optional Two Row Canopy Optional Three Row Canopy Connector 4 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band 3 Row Canopy B 4 ft 6 ft or 8 ft 12 f...

Page 7: ...components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Five Rows of Shelves 4 ft...

Page 8: ...L 6 6 R BL R BL R BL 6 6 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground a...

Page 9: ...L R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNI...

Reviews: