ESTIMATED SHIPPING WEIGHT 

5

Case

Solid End

4 ft

6 ft

8 ft

12 ft

(each)

lb 

(kg)

800 (363)

1000 (454)

1100 (499)

1500 (680)

100 (45)

5

Actual weights will vary according to optional kits included.

5 of 9

P/N 0486353_B

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

Impact  

Excel

M5NX-GEP

Meat and Delicatessen

Product Data

ARI Refrigerated Volume 

(Cu Ft/Ft)

8.25 ft

3

/ft  (0.77 m

3

/m)

Recommended Usable Cube 

2  

(Cu Ft/Ft)

5.74 ft

/ft  (0.53 m

/m)

ARI Total Display Area 

3  

(

Sq Ft/Ft)

4.28 ft

2

/ft  (1.30 m

/m)

Shelf Area 

4

(Sq Ft/Ft)

6.94 ft

2

/ft  (2.12 m

/m)

1

Computed using ARI 1200 standard methodology: Refrigerated Volume, ft

3

[m

3

]/Unit of Length, ft [m]

2

ARI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft

3

/ft [m

3

/m]

3

Computed using ARI 1200 standard methodology:  Total Display Area, ft

2

[m

2

]/Unit of Length, ft [m]

4

Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann 

Product Reference Guide

. The standard shelf complement for this model is (1) row of 12-inch shelf, 

(1) row of 14-inch shelf and (1) row of 16-inch shelf.

eparately from fans.

Summary of Contents for M5NX-GEP

Page 1: ...4780446 6 Ft Only A 7W Standard Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780...

Page 2: ...0 2 3 4 70 2 3 4 70 2 3 4 70 Electrical Service Electrical Field Wiring connection point B RH End of case to center of stub up area 36 1 4 921 60 1 4 1530 84 1 4 2140 132 3 8 3363 Back of case to cent...

Page 3: ...determine PSIG conversions Estimated Charge lb M5NX GEP 4 ft 1 9 6 ft 2 5 8 ft 3 7 12 ft 5 1 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a po...

Page 4: ...ing T 8 fluorescent Additional 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Additional 2 Row Canopy 0 51 1 02 1 02 1 54 59 118 118 170 Additional 3 Row Canopy 0 77 1 53 1 53 2 31 89 177 177 255 1 Row...

Page 5: ...lay Area 3 Sq Ft Ft 4 28 ft2 ft 1 30 m2 m Shelf Area 4 Sq Ft Ft 6 94 ft2 ft 2 12 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refrigerated V...

Page 6: ...3 3 4 4 4 4 4 4 Optional Two Row Canopy Optional Three Row Canopy Connector 4 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band 3 Row Canopy B 4 ft 6 ft or 8 ft 12 f...

Page 7: ...components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Five Rows of Shelves 4 ft...

Page 8: ...L 6 6 R BL R BL R BL 6 6 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground a...

Page 9: ...L R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNI...

Reviews: