background image

M5NX-GEP

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

6 of 9

Refrigeration 

Thermostat

2

To 
Condensing 
Unit

}

Light Blue

1, 2 & 3 Fans

120V N

EUTRAL

B

ROWN

  B

AND

120V P

OWER

Fans

1

B

ROWN

  B

AND

 

 1 Fan 

 

 2 Fans 

 

 2 Fans 

 

 3 Fans

4 ft 
6 ft 
8 ft 

12 ft

12 ft

4

4

3

3

3

4

4

4

4

4

4

Optional 

Two Row 

Canopy

Optional 

Three Row 

Canopy

Connector

4

BL

W

BL

W

G

R

BL

W

B

R

R

R

BL

BL

R

BL

R

R

R

BL

BL

R

BL

R

R

R

B

B

Orange or Tan Band

 

 

                                      3 Row Canopy

B

4 ft

6 ft or 8 ft

12 ft

 

 

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

=  F

IELD

 G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

=  C

ASE

 G

ROUND

Fan Wiring
Offtime Defrost

Light Circuits

Summary of Contents for M5NX-GEP

Page 1: ...4780446 6 Ft Only A 7W Standard Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780...

Page 2: ...0 2 3 4 70 2 3 4 70 2 3 4 70 Electrical Service Electrical Field Wiring connection point B RH End of case to center of stub up area 36 1 4 921 60 1 4 1530 84 1 4 2140 132 3 8 3363 Back of case to cent...

Page 3: ...determine PSIG conversions Estimated Charge lb M5NX GEP 4 ft 1 9 6 ft 2 5 8 ft 3 7 12 ft 5 1 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a po...

Page 4: ...ing T 8 fluorescent Additional 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Additional 2 Row Canopy 0 51 1 02 1 02 1 54 59 118 118 170 Additional 3 Row Canopy 0 77 1 53 1 53 2 31 89 177 177 255 1 Row...

Page 5: ...lay Area 3 Sq Ft Ft 4 28 ft2 ft 1 30 m2 m Shelf Area 4 Sq Ft Ft 6 94 ft2 ft 2 12 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refrigerated V...

Page 6: ...3 3 4 4 4 4 4 4 Optional Two Row Canopy Optional Three Row Canopy Connector 4 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band 3 Row Canopy B 4 ft 6 ft or 8 ft 12 f...

Page 7: ...components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Five Rows of Shelves 4 ft...

Page 8: ...L 6 6 R BL R BL R BL 6 6 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground a...

Page 9: ...L R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNI...

Reviews: