1-14
I
nstallatIon
P/N 0515388_L
U.S. & Canada 1-800-922-1919 • Mexico 01-800-890-2900 • www.hussmann.com
HOOK SEISMIC RESTRAINT
BRACKET OVER BASE RAIL
AND TIGHTEN AFTER CASE IS
IN PLACE
SQUARE
PLATE WASHER
ANCHOR-WEDGE
3/4-10 x 4-3/4
SEE NOTES
REACH UNDER
CASE TO INSTALL
BRACKET
FRONT BACK
SEE NOTES
MINIMUM
DEPTH 3-3/8 INCHES
MAXIMUM
DEPTH 3-7/8 INCHES
FIELD INSTALLATION OF SEISMIC RESTRAINTS
3/4-10 NUT
SEISMIC
RESTRAINT
BRACKET
Notes
Determine hole locations and set all anchors before case
is in place. Avoid obstructions under case or on floor when
planning anchor locations. Two brackets required at each
case joint and case end. See plan view. Equal number of
brackets should be on front and back of case.
PLAN (TOP) VIEW
ANCHORS REPRESENTED BY “X”
CASE LINEUP
STANDALONE CASE
INSTALLING SEISMIC RESTRAINTS
Door cases may require restraints in locations
where cases are subject to potential seismic
activity or in any instances where there is the
potential for unwanted movement or tipping
of the case(s).
To install these restraints:
Determine hole locations and set all anchors
before case is in place. Avoid obstructions
under case or on floor when planning anchor
locations. Two brackets are required at each
case joint and case end. See plan view on the
next page. Equal number of brackets should
be on front and back of case.