2-4
ELECTRICAL / REFRIGERATION
P/N 2400204_H
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • www.hussmann.com
START-UP / OPERATION
The defrost cycle is initiated at power on. (This
cycle will quickly terminate on the initial start-
up of a warm merchandiser.) Another defrost
cycle will follow every 8 hours thereafter. The
defrost times will reset whenever power is inter-
rupted. Therefore, the standard defrost times
can be reset by interrupting power (full stop,
then start) at the desired time. This will reset
the initial time and restart the 8-hour cycle.
During the compressor-on time (1 minute),
or compressor-off time (2 minutes), built-in
protection time will delay the defrost initiation.
If you force a defrost cycle during this time,
the feature will initiate but not start until the
compressor protection mode times out.
ALARMS AND CODES
Safe-NET III is available with an audible
alarm (located in the display module) that
sounds in the event a failure occurs.
f
lashing
t
emperature
or
s
ensor
a
larm
led, e1
or
e2
If the Temperature or Sensor Alarm LED (red)
on the controller and display is flashing, a
temperature sensor has failed (or sensor is
disconnected). The display shows E1 if the case
sensor has failed (or disconnected) or E2 if the
evaporator sensor has failed (it is disconnected).
If the merchandiser sensor fails, refrigeration
will run continuously. Turn off, or repeat a
duty cycle of a few minutes on and a few
minutes off.
TROUBLESHOOTING
Alarm
or Code
Indicates
Action
Red LED
• Firmware
• Call Service
remains ON
corruption on
immediately
after startup
controller
• Controller is
not operating
Red LED turns • Case
• Make sure the door
on during
temperature
is closed
operation
is too warm
• Make sure that cold
or too cool
air is not being
blocked or deflected
• Check the
temperature using
the optional display
or a thermometer
• If the LED does not
turn off after an hour,
call Service
Red LED
• Temperature • Check the optional
flashes
sensor failure
display for error code
• E1 indicates E1 or E2 and call
a case
Service immediately
temperature
failure
• E2 indicates
an evaporator
temperature
sensor failure