2-6
ELECTRICAL / REFRIGERATION
P/N 2400204_H
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • www.hussmann.com
TEMPERATURE ADJUSTMENT
1.
Rotate the adjustment knob counter clock-
wise for a warmer setpoint or clockwise for
a colder setpoint.
2.
While adjusting the temperature, the display
shows the setpoint (cut out value). A few
seconds after the temperature is set, the
controller reverts to the sensed temperature
in the merchandiser.
3.
To verify merchandiser settings, turn the
dial to warm and cold as shown above.
Output readings should be within one
degree of the temperatures shown above.
The control has protective settings to prevent
short cycling of the compressor.
A. The compressor may run for up to 60 sec.
after Step 2 is completed. Start the 10 sec.
count down for Step 3, once the display is
blank.
B. The defrost initiation may be delayed for
up to 120 sec. after Step 3 is completed.
7
6
COLD
WARM
1
2
4
3
5
Display - at Full Cold
Model LTH
Display - at #1 Position
Model LTH
7
6
COLD
WARM
1
2
4
3
5
"OFF" Position
Safe-NET III Control
Set at Full Cold Position
Safe-NET III Control
# 1 Position