P/N 2400204_H
3-1
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
Service Deli Merchandisers
START UP
Follow the start up procedures as detailed in
Section 2 of this manual.
Each self contained merchandiser has its own
evaporator coil. NAV/C models have capillary
tubes as expansion devices.
a. Check the interior cabinet thoroughly
for loose nuts, bolts and electrical
connections.
b. Inspect the refrigeration lines for visible
damage or chafing.
c. Replace electrical box cover and access
panel if previously removed.
d. Turn on the electrical power, power
switch and start the merchandiser.
The merchandiser must pull down in
temperature.
Allow merchandiser 24 hours to operate
before loading product.
1. The Safe-NET III Controller controls
refrigeration temperature. This is factory
installed in the control panel. Adjust this
control knob to maintain the discharge air
temperature shown. Measure discharge air
temperatures at the center of the discharge air
opening.
Defrosts are time initiated and temperature
terminated for self contained. The defrost
setting is factory set as shown above.
To ensure a thorough defrost, defrost must be
terminated by the temperature termination
setting — not by time.
START UP / OPERATION
60
1
Summary of Contents for NAV Series
Page 2: ......
Page 4: ......
Page 42: ...Hussmann Corporation 12999 St Charles Rock Road Bridgeton MO 63044 2483 www hussmann com ...