PROBLEM
Warm storage temperature
Compressor runs
continuously; product
too warm
Compressor runs
continuously;
product too cold
PROBABLE CAUSE
1. Temperature control not
set properly
2. Short or refrigerant
3. Cabinet location too
warm
4. Refrigerant over-charge
5. Low voltage, compressor
cycling on overload
1. Short of refrigerant
2. Warm ambient temperature
3. Product past loadline
1. Defective control
2. Control sensing element
not in positive contact
3. Short on refrigerant
SOLUTION
1. Reset control
2. Leak check, replace drier
evacuate and recharge
3. Move to cooler location or
correct excessive heat source
4. Purge system, evacuate
and recharge
5. Compressor voltage must not
be more than 5% below rating
1. Leak check, replace drier,
evacuate and recharge
2. Decrease ambient temperature
3. Product past load line
1. Replace
2. Assure proper contact
3. Leak check, replace drier
evacuate and recharge
TROUBLESHOOTING LIGHT GUIDE
PROBLEM
Lights won’t start
Lights flicker
SOLUTION
1. Check light switch
2. Check continuity to ballast
3. Check to see if bulbs are inserted properly
in sockets
4. Check voltage
1. Allow lamps to warm up
2. Check lamp sleeve for cracks
3. Check sockets for moisture and proper
contact
4. Bulb replacement may be necessary
5. Check voltage
6. New bulbs tend to flicker until used